Inspection
Inspection Details
Equipment ID
1262
1262
Inspection Date
7/23/2018
7/23/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Gary Beadle
Gary Beadle
Mechanic Name
Thomas Droege
Thomas Droege
Relief Valve Pressure
Slide
Governor Rope Pull
Door Closing Force
External ID
0bdb2aed-ffd3-4543-816f-91b77271d0f2
0bdb2aed-ffd3-4543-816f-91b77271d0f2
Location
St. Louis Gateway Transportation Center
430 S 15TH ST, SAINT LOUIS, MO
430 S 15TH ST, SAINT LOUIS, MO
Owner
City of St. Louis
1200 MARKET ST RM 301, SAINT LOUIS, MO 63103-2806
1200 MARKET ST RM 301, SAINT LOUIS, MO 63103-2806
Billing
Attn: St. Louis Gateway Transportation Center
430 S 15TH ST, SAINT LOUIS, MO 63103-2607
430 S 15TH ST, SAINT LOUIS, MO 63103-2607
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 8.1 - Machinery space access, lighting, receptacle, and condition | 8.1 | Provide clean down of unit. | 8/16/2022 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 8.12 - Steps, step chains, and trusses | 8.11.4.2.12 | Observed numerous damaged and broken step demarcation indicators that shall be repaired or replaced as needed. | 8/10/2020 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 8.1 - Machinery space access, lighting, receptacle, and condition | 8.11.4.2.1 (Re-Inspection) | Existing upper and lower demarcation lights shall work. | 8/16/2022 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.5 - Lighting | 8.6.11.5(i) Demarcation Lighting (Re-Inspect) | x | The demarcation lights shall be operational. | 9/20/2021 | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.9 - Steps and upthrust device | 8.6.8.6.1 Steps with broken treads shall be repaired or replaced | x | x | Replace the broken step tread. | 9/20/2021 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.13 Escalator Cleaning | Unit shall have a clean-down performed. | 8/16/2022 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.19 - Maintenance records | 8.6.1.4 | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided. (This item is for notification purposes for future violation in 2022) | 8/16/2022 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Certificate | A current MO State operating certificate shall be obtained and displayed. | 8/16/2022 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.5 - Lighting | 8.6.11.5(i) Demarcation Lighting (Re-Inspect) | x | Upper & lower step demarcation lighting not working. | 7/19/2024 | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.17 - Step/skirt clearances, panels, and performance index | 8.6.8.3 Step/Skirt Performance Index | x | Performance index testing graphs, including loaded gap, CoF, Index, etc. to be sent to inspector for verification of results. Note: Step indexing machine broke after completion of this testing. | 7/19/2024 | |
| Missouri Minimum : Escalators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | Testing Incomplete: Only performance index testing and handrail condition tested. | 7/31/2024 | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.3 - Handrails | 6.1.3.4 (Hand rails) (Re-Inspection) | x | Handrails will be free of major cracks and pinch-points. Replace left handrail. | 7/31/2024 | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Certificate | A current MO State operating certificate shall be obtained and displayed. | 11/24/2025 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.3 - Handrails | 6.1.3.4 (Hand rails) (Re-Inspection) | x | Handrails will be free of major cracks and pinch-points. Replace left handrail. - Violation not corrected as of 7/31/24 re-inspection to complete testing. | 7/7/2025 | |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.1 Escalator Handrails | x | Handrails will be free of major cracks and pinch points. Replace left handrail. Violation originally cited in 2024 still not corrected. 45 days to correct at which point unit will be red tagged until corrected. | ||
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.3 Step/Skirt Performance Index | x | Step Index Performance Testing shall be performed and confirmed compliant. Graph to be provided. | ||
| Missouri Minimum : Escalators | CSR 40-5.100 State Operating Certificate | 5.100(2) display of certificate | A current MO State operating certificate shall be posted near the equipment, in a noncombustible frame with a clear protective vision plate over it. | 11/24/2025 |