Inspection
Inspection Details
Equipment ID
9603
9603
Inspection Date
1/13/2023
1/13/2023
Inspection Type
Reinspection
Reinspection
Inspector Name
David Folkert
David Folkert
Mechanic Name
Jason Stout
Jason Stout
Relief Valve Pressure
Na
Na
Slide
Governor Rope Pull
Door Closing Force
Na
Na
External ID
61bf28d2-8d6e-42b5-864e-f9f57dd01307
61bf28d2-8d6e-42b5-864e-f9f57dd01307
Location
Boehringer Ingelheim Vetmedica Inc
2621 N BELT HWY, SAINT JOSEPH, MO
Phone: (816) 351-3568
2621 N BELT HWY, SAINT JOSEPH, MO
Phone: (816) 351-3568
Owner
Attn: Robert Davis
Boehringer Ingelheim Animal Health Inc.
2621 N Belt Hwy, St. Joseph, MO 64506
Phone: (816) 236-8222
Email: robert.davis@boehringer-ingelheim.com
Boehringer Ingelheim Animal Health Inc.
2621 N Belt Hwy, St. Joseph, MO 64506
Phone: (816) 236-8222
Email: robert.davis@boehringer-ingelheim.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | audible signal does not operate on fire service phase 1 operation. | 8/5/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Door Systems 8.6.4.13 (Re-Inspection) | Yes | No | install cover over exposed 110 volt wiring on car door operator. | 4/12/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | Yes | No | emergency light and bell do not operate. | 4/12/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | post emergency evacuation of passengers procedure form inside machine room. | 3/15/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | hall firefighter keyswitch identification markings are illegible. "on-off-byp" | 3/15/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.9 Cleaning of Top of Cars | No | No | clean debris from top of car and remove oil cans. | 3/15/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.2 Oil Leakage Collection | No | No | cylinder drain needs to be removed from hydraulic tank and ran to container in pit not to exceed 5 gallons. | 3/15/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | remove rags and absorbent pads from machine room floor. | 3/15/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.1 General Maintenance Requirements Documentation | No | No | No maintenance control plan on site | 3/21/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | No maintenance records on site | 3/21/2023 |
| MO Minimum : Elevators | (O) - Existing Hydraulic Elevators | (O)4 (Re-Inspection) | Yes | No | Repair or replace hydraulic control valve. Elevator drifts down 3 inches in 15 minutes unless hydraulic line shut off is closed. | 1/13/2023 |
| MO Minimum : Elevators | (O) - Existing Hydraulic Elevators | (O)2(B) | No | No | Perform full load pressure test and seal relief pressure setting with inspector present. The hydraulic control /relief valve has been replaced. | 2/13/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | Post In Case of Fire signage next to hall button fixture | 11/2/2023 |