Inspection
Inspection Details
Equipment ID
15006
15006
Inspection Date
1/30/2023
1/30/2023
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
Thomas Krug
Thomas Krug
Mechanic Name
Thomas Moore
Thomas Moore
Relief Valve Pressure
360
360
Slide
Governor Rope Pull
Door Closing Force
24/25
24/25
External ID
d6efdcba-3cf4-4b82-bbd3-29f9f3822bc9
d6efdcba-3cf4-4b82-bbd3-29f9f3822bc9
Location
Adams Elementary
1311 TOWER GROVE AVE, SAINT LOUIS, MO
Phone: (660) 646-5436
1311 TOWER GROVE AVE, SAINT LOUIS, MO
Phone: (660) 646-5436
Owner
Attn: Rosmon Johnson
St. Louis Board of Education
801 N 11th St, St. Louis, MO 63101
Phone: (314) 535-2500
Email: Rosmon.Johnson@slps.org
St. Louis Board of Education
801 N 11th St, St. Louis, MO 63101
Phone: (314) 535-2500
Email: Rosmon.Johnson@slps.org
Billing
Attn: Cardinal Elevator
Cardinal Elevator
2851 Barrett Station Rd, St. Louis, MO 63021
Phone: (314) 939-9222
Email: lisa@cardinalelevator.com
Cardinal Elevator
2851 Barrett Station Rd, St. Louis, MO 63021
Phone: (314) 939-9222
Email: lisa@cardinalelevator.com
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
conversion | conversion | conversion - reinspect | x | Phase 2 Firemans return call cancel does not operate. | 7/18/2018 | |
A17.1-1996 : Elevators | 2.5 - Housekeeping | 1001.2(b)(5) | Machine room shall not be used to store non-elevator related materials. | 10/26/2020 | ||
A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7 | Emergency lighting is not operational. | 10/26/2020 | ||
A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 1001.2(d)(12) | x | x | Car call cancel does not function on Phase 2 fire service. | 7/31/2019 |
A17.1-1996 : Elevators | 2.5 - Housekeeping | 1001.2(b)(5) | The machine room shall not be used for the storage of non-elevator related items. | 10/26/2020 | ||
A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | The elevator pit shall be kept clean and dry. | 10/26/2020 | ||
A17.1-1996 : Elevators | 2.5 - Housekeeping | 1001.2(b)(5) | The machine room shall not be used for the storage of non-elevator related items. | 10/26/2020 | ||
MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | There were no keys on site to test fire service. Keys shall be kept on site and fire service shall be tested. | 10/20/2020 | |
A17.1-1996 : Elevators | 2.5 - Housekeeping | 1001.2(b)(5) | Remove all non-elevator related items from the elevator machine room. | |||
A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | |||
A17.1-1996 : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing | This elevator is equipped with an over speed valve and is due for a category 5 test. A category 5 test shall be performed on the over speed valve in 2021 or 2022. The valve shall be sealed and tagged after the category 5 test. | |||
A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current MO state operating certificate shall be displayed in the elevator machine room. | |||
A17.1-1996 : Elevators | 1.17 - Standby power operation | 1002.2g (Standby Power Operation) | x | Emergency battery lowering shall be operational. | 1/30/2023 | |
A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | The pit sump shall have a cover in place. | |||
MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Post current State Elevator Certificate. | |||
MO Minimum : Elevators | (A) - Hoistways | (A)9 | Unable to check in car stop switch upon Phase I recall,no key. |