Inspection
Inspection Details
Equipment ID
25494
25494
Inspection Date
2/2/2023
2/2/2023
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Sean Carmody
Sean Carmody
Mechanic Name
Jeffrey Miller
Jeffrey Miller
Relief Valve Pressure
390
390
Slide
Governor Rope Pull
Door Closing Force
18
18
External ID
d3088e65-b586-4622-88c4-8e29f4de4c88
d3088e65-b586-4622-88c4-8e29f4de4c88
Location
Loy Lange Box Company
222 Russell Blvd, St. Louis, MO
Phone: (314) 776-4712
Email: Mreynolds@loylangebox.com
222 Russell Blvd, St. Louis, MO
Phone: (314) 776-4712
Email: Mreynolds@loylangebox.com
Owner
Attn: Matt Reynolds
Loy Lange Box Company
222 Russell Blvd, St. Louis, MO 63104
Phone: (314) 776-4712
Email: Mreynolds@loylangebox.com
Loy Lange Box Company
222 Russell Blvd, St. Louis, MO 63104
Phone: (314) 776-4712
Email: Mreynolds@loylangebox.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | No | All smokes, machine room heat, shunt trip, and pit sprinkler flow switch shall be tested. | 12/16/2021 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | Yes | No | The building corridors shall be so lighted that the illumination at the landing sills, when an elevator is in service, shall be not less than 10 foot-candles. | 12/16/2021 |
| A17.1-2016 : Elevators | 1.6 - Car emergency signal | 8.10.2.2.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | The in car emergency telephone shall be operational. | 12/16/2021 |
| A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 3.27.3 Device Actuation at Recall Level | Yes | Yes | When sprinklers are installed in elevator pits, automatic fire detection shall be installed to initiate elevator recall in accordance with 3.27. A waterflow switch shall be permitted to initiate elevator recall upon activation of a sprinkler installed in the elevator pit, provided the waterflow switch and pit sprinkler are installed on a separately valved sprinkler line dedicated solely for protecting the elevator pit, and the waterflow switch is provided without time-delay capability. Note: the flow switch shall activate the fire hat and alternate floor recall. | 12/16/2021 |
| A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.9 Elevator Corridor Call Station Pictograph | Yes | No | A sign shall be posted adjacent to hall call fixtures instructing occupants not to use the elevator in case of a fire, the sign shown in A17.1 2016, figure 2.27.9 shall be provided. The sign shall include only the wording and graphics shown in figure 2.27.9. | 12/16/2021 |
| A17.1-2016 : Elevators | 2.3 - Lighting and receptacles | 8.10.3.2.2(h) | Yes | No | At least one duplex GFCI receptacle shall be provided in the machine room. | 12/16/2021 |
| A17.1-2016 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.10.3.2.5(a) | Yes | No | Illumination of the pit shall not be less than 10 foot-candles measured at the pit floor. | 12/16/2021 |
| A17.1-2016 : Elevators | 3.13 - Windows, projections, recesses, and setbacks | 3.1 | Yes | No | Exposed fasteners protruding into the hoistway from the ceiling and walls shall be removed. | 12/16/2021 |
| A17.1-2016 : Elevators | 3.13 - Windows, projections, recesses, and setbacks | 2.1.6 | Yes | No | Where recesses or setbacks exceeding 4 inches occur in the enclosure wall, the top of the recess or setbacks shall be beveled at and angle of not less than 75 degrees with the horizontal. | 12/16/2021 |
| A17.1-2016 : Elevators | 2.1 - Access to machine space | 2.7.1.1 | No | No | Label the machine room door in case of emergency. | 2/16/2023 |
| A17.1-2016 : Elevators | 1.6 - Car emergency signal | 2.11.1.3 Emergency Phone not workng Alarm Functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | The phone shall establish 2-way communication. | 12/4/2025 |