Inspection
Inspection Details
Equipment ID
3657
3657
Inspection Date
2/14/2023
2/14/2023
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Wayne Ingram
Wayne Ingram
Mechanic Name
Jeremiah Dugger
Jeremiah Dugger
Relief Valve Pressure
Slide
Stopped Level
Stopped Level
Governor Rope Pull
NA / NA
NA / NA
Door Closing Force
15
15
External ID
8096ff0f-5132-44a6-a62d-24dcab2cb92a
8096ff0f-5132-44a6-a62d-24dcab2cb92a
Location
Sky 11
331 Park Central E, Springfield, MO
Phone: (417) 217-9878
331 Park Central E, Springfield, MO
Phone: (417) 217-9878
Owner
Attn: Kelly Harris
Woodruff Historic Building, LLC
128 Park Central E, Springfield, MO 65806
Phone: (417) 895-8015
Email: kharris@ahmliving.com
Woodruff Historic Building, LLC
128 Park Central E, Springfield, MO 65806
Phone: (417) 895-8015
Email: kharris@ahmliving.com
Billing
Attn: Woodruff Historic Building, LLC
Woodruff Historic Building, LLC
305 W Commercial St, Springfield, MO 65803
Phone: (000) 000-0000
Email: info@liveatparkeast.com
Woodruff Historic Building, LLC
305 W Commercial St, Springfield, MO 65803
Phone: (000) 000-0000
Email: info@liveatparkeast.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Need current operating certificate posted in machine room. | 5/15/2024 |
| conversion | conversion | n/a | No | No | Gate switch breaks over 2"- Reduce/adjust | 5/15/2024 |
| conversion | conversion | n/a | No | No | Replace GFCI in pit | 5/15/2024 |
| conversion | conversion | n/a | No | No | Door torque over 30 pounds. Adjust | 5/15/2024 |
| conversion | conversion | n/a | No | No | Need current fire extinguisher in machine room | 5/15/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Need current operating certificate | 10/16/2023 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Clean Machine Room | 5/15/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Phone failed | 2/14/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.1 General Maintenance Requirements Documentation | No | No | No Maintenance Records | 5/15/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Install Gard rail on ladder that allows egress to machine room (height of approximately 25' with an angle of 70% ) | 5/15/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.11.1 Firefighters' Emergency Operation & Documentation | No | No | Fireman's recall is to be checked monthly | 5/15/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Phase I key switch requires replacing | 5/15/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | No Records | 4/3/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Ladder for Egress/Access to equipment room needs a back cover ladder approximately 25' @ an angle of about 75 degree. | 4/3/2026 |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | Yes | No | Ropes under sized | 5/20/2024 |