Inspection
Inspection Details
Equipment ID
5652
5652
Inspection Date
2/2/2023
2/2/2023
Inspection Type
Reinspection
Reinspection
Inspector Name
Cynthia "CJ" Brady
Cynthia "CJ" Brady
Mechanic Name
Jake Brennan
Jake Brennan
Relief Valve Pressure
NA
NA
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
NA
NA
External ID
5e3979ce-1a10-46e5-9ec1-165c977f64a8
5e3979ce-1a10-46e5-9ec1-165c977f64a8
Location
Ackert Park SCC
894 LELAND AVE, SAINT LOUIS, MO
Phone: (314) 726-4767
894 LELAND AVE, SAINT LOUIS, MO
Phone: (314) 726-4767
Owner
Attn: Ackert Park
Ackert Park
894 Leland Ave, University City, MO 63130
Phone: (000) 000-0000
Email: marycarol@avalongarden1920.com
Ackert Park
894 Leland Ave, University City, MO 63130
Phone: (000) 000-0000
Email: marycarol@avalongarden1920.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.3 - Lighting and receptacles | 8.11.2.1.2(c) | Make all machine room lighting operational. | 2/14/2019 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | All the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 8/12/2021 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing | This elevator is equipped with an over speed valve that in not sealed. A category 5 test shall be performed on the over speed valve in 2021 or 2022. The valve shall be sealed and tagged after the category 5 test. | 8/12/2021 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.2-2.27.8 | x | x | Phase 1 fire service is operating erratically. Firemans' return shall be repaired and tested for compliance, including initiating devices and wiring. Elevator Red Tagged. | 1/31/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.11 Periodic Inspection and Test. | x | Annual inspection and category 5 test of overspeed valve had to be stopped due to fire service issue and elevator being red tagged. Complete annual inspection and category 5 testing of overspeed valve still needs to be completed. | 1/31/2022 | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.11 Periodic Inspection and Test. | x | Annual inspection and category 5 test of overspeed valve had to be stopped due to fire service issue and elevator being red tagged. Complete annual inspection and category 5 testing of overspeed valve still needs to be completed. | 3/7/2022 | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.5 Illumination of Pits | The pit light shall be operational. | 7/13/2022 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.3 Guards Between Adjacent Pits | The GFCI in the pit shall be operational. | 7/13/2022 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 8.6.11.1 Firefighters Emergency Operation: Monthly Testing | A record of findings for firefighters' service operation, tested monthly as required by 8.6.11.1 with identification of the person(s) that performed the operation, and the date shall be available on-site. | 2/9/2023 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 8.11.2.2.6 Fire Fighters Operation (Re-Inspection) | x | When the elevator is in Phase 2 fire service operation with the phase 2 switch in the "HOLD" position, the elevator car shall remain at the landing. | 2/2/2023 | |
| MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)4 | Repair car top panels to safely sustain load of 200 lbs. (front two panels have broken welds and mesh is damaged). | 2/7/2024 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | The phone shall establish 2-way communication. | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | Pit shall be clean and dry. |