Inspection
Inspection Details
Equipment ID
13047
13047
Inspection Date
2/14/2023
2/14/2023
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
Curtis Belew
Curtis Belew
Mechanic Name
John Palmer, Jr
John Palmer, Jr
Relief Valve Pressure
465
465
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
22F/24R
22F/24R
External ID
28db168e-adf6-4aa7-894b-ae6c140e8de4
28db168e-adf6-4aa7-894b-ae6c140e8de4
Location
St. Charles Police & Municipal Bldg
1781 Zumbehl Rd, St. Charles, MO
Phone: (636) 949-3300
1781 Zumbehl Rd, St. Charles, MO
Phone: (636) 949-3300
Owner
Attn: City of St. Charles- Police Bldg
City of St. Charles- Police Bldg
1781 Zumbehl Rd, St. Charles, MO 63303
Phone: (000) 000-0000
City of St. Charles- Police Bldg
1781 Zumbehl Rd, St. Charles, MO 63303
Phone: (000) 000-0000
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | In car emergency telephone shall work. | 3/2/2020 |
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 2/18/2022 |
| A17.1-1996 : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing | No | No | This elevator is equipped with an overspeed valve that in not sealed. A category 5 test shall be performed on the overspeed valve on or before the next annual inspection. The valve shall be sealed and tagged after the category 5 test. | 3/10/2023 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 3/10/2023 |
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. | 3/10/2023 |
| A17.1-1996 : Elevators | 3.16 - Traveling cables and junction boxes | 1001.2(c)(22) | No | No | The wiring bound to the traveling cables is not listed or approved for use as an elevator traveling cable. It shall be removed or replaced with an approved type. | 3/10/2023 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 3/7/2023 |
| A17.1-1996 : Elevators | 3.16 - Traveling cables and junction boxes | 102.1 | No | No | The traveling cables shall be hung properly. | 3/7/2023 |
| A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1206.1h | No | No | An ABC fire extinguisher with a current test tag shall be mounted in the machine room located convenient to the access door. | 3/7/2023 |
| A17.1-1996 : Elevators | 1.12 - Car enclosure | 211.9 | No | No | Tighten/repair car interior handrail. | 10/30/2024 |
| A17.1-1996 : Elevators | 2.8 - Pipes, wiring, and ducts | 102.1 | No | No | 4x4 electrical box in machine room needs to have wiring inside box and cover installed. | 10/30/2024 |