Inspection
Inspection Details
Equipment ID
960
960
Inspection Date
2/24/2023
2/24/2023
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Paul Karrenbrock
Paul Karrenbrock
Mechanic Name
Jake Brennan
Jake Brennan
Relief Valve Pressure
na
na
Slide
na
na
Governor Rope Pull
na
na
Door Closing Force
25
25
External ID
527959ca-a2a2-417b-9ba2-274f546e7f7f
527959ca-a2a2-417b-9ba2-274f546e7f7f
Location
University Square Apartments
605 Leland Ave, University City, MO
Phone: (314) 727-6264
605 Leland Ave, University City, MO
Phone: (314) 727-6264
Owner
Attn: University Square Company, a MO LLC
University Square Company, a MO LLC
6631 Delmar Blvd, University City, MO 63130
Phone: (314) 727-6264
Email: theloopapartments@gmail.com
University Square Company, a MO LLC
6631 Delmar Blvd, University City, MO 63130
Phone: (314) 727-6264
Email: theloopapartments@gmail.com
Billing
Same as Owner
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
MO Minimum : Elevators | (I) - Pits | (I)1 | The elevator pit floor is covered in water. The elevator pit shall be kept clean and dry. | 3/8/2019 | ||
MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | The elevator pit light did not work on the day of inspection, repair for proper illumination of the pit floor. | 3/8/2019 | ||
MO Minimum : Elevators | (I) - Pits | (I)1 | The elevator pit floor is covered in water. The elevator pit shall be kept clean and dry. | 2/21/2020 | ||
MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | The elevator pit light did not work on the day of inspection, repair for proper illumination of the pit floor. | 2/21/2020 | ||
MO Minimum : Elevators | (F) - Electrical Switches | (F)2 | x | The final and normal limit switches shall be adjusted to operate for proper run-by of the counterweight and buffer. Reinspection required. | 3/12/2021 | |
MO Minimum : Elevators | (I) - Pits | (I)1 | The elevator pit floor is covered in water. The elevator pit shall be kept clean and dry. | 3/21/2021 | ||
MO Minimum : Elevators | (S) - Fire Service | 211.3a(8) Visual and audible signal | The fireman's emergency service phase I and II operations was tested and the following deficiency was noted: The visual signal device did not light in the car when phase I was activated. Reinspection required. | 3/12/2021 | ||
MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | x | Govenor rope shall be replaced due to rusting. Re-inspection required | 3/21/2022 | |
MO Minimum : Elevators | (F) - Electrical Switches | (F)9 | x | Sprinkler heads have been added to the elevator machine room, top of the elevator hoistway, and elevator pit without the required heat detectors to activate the shunt trip disconnect before the application of water. Heat detectors shall be installed within 2’ of each sprinkler head to activate the shunt trip disconnect. | ||
MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | x | A17.1 1996 2.11.3b With the addition of sprinklers at the top of the hoistway, smoke detectors are now required and shall be tied into the elevator controller for proper fireman phase I recall operation. | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | There is a bottom guide roller on the counterweight that is cracked and shall be replaced. | |||
MO Minimum : Elevators | (S) - Fire Service | 211.7 Firefighters Operations/Signage | There is no signage for Firefighters Operation by the phase I key switches. Obtain the correct signage from the building code addition that this elevator was designed to meet. | |||
MO Minimum : Elevators | (I) - Pits | (I)1 | The elevator pit floor is covered in water. The elevator pit shall be kept clean and dry. | |||
MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | The pit light fixture failed to illuminate in the pit. Repair pit light fixtures to provide lighting of not less than five (5) foot candles at the pit floor for maintenance and emergency personnel. |