Inspection
Inspection Details
Equipment ID
13410
13410
Inspection Date
3/10/2023
3/10/2023
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Steven Salabay
Steven Salabay
Mechanic Name
Jeff Setchfield
Jeff Setchfield
Relief Valve Pressure
320
320
Slide
NA
NA
Governor Rope Pull
NA/NA
NA/NA
Door Closing Force
21
21
External ID
53cf1399-3c9e-4839-a6fe-e347f67a2754
53cf1399-3c9e-4839-a6fe-e347f67a2754
Location
Holiday Inn-St. Louis Downtown
811 N 9th St, St. Louis, MO
Phone: (314) 421-4000
811 N 9th St, St. Louis, MO
Phone: (314) 421-4000
Owner
Attn: HMA Hotels
Holiday Inn-St.Louis Downtown Convention Center
811 N 9th St, St. Louis, MO 63101
Phone: (314) 421-4000
Fax: (314) 421-5974
Email: Rwhitnah@hmahotels.com
Holiday Inn-St.Louis Downtown Convention Center
811 N 9th St, St. Louis, MO 63101
Phone: (314) 421-4000
Fax: (314) 421-5974
Email: Rwhitnah@hmahotels.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Remove Oil from pit floor | 7/15/2019 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Clean pump unit from drip pan | 7/15/2019 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Clean oil from Machine room floor | 7/15/2019 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Repair machine room door lock | 7/15/2019 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State Certificate in machine room | 7/15/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Unit out of service. Make all repairs in order for an inspection to occur. | 4/27/2022 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Remove oil from pit floor | 4/27/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | Provide a complete maintenance control program and include oil log | 4/27/2022 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Repair machine room lighting | 4/27/2022 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform monthly fire service test and document on log in machine room | 4/27/2022 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Remove oil from pit floor. Sump hole filled with oil spilling out all over floor. Written up last years inspection | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Car emergency communications not working | 3/13/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Repair machine room lighting | |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform monthly fire service testing and document on log in machine room | |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Remove oil from pit floor. Reinspection required within 14 days. Fire hazard | |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform monthly fire service testing and document on log in machine room | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current state certificate in machine room | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Repair phone in car . Reinspection required within 14 days | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Repair emergency light in car |