Inspection
Inspection Details
Equipment ID
13732
13732
Inspection Date
3/28/2023
3/28/2023
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
Thomas Krug
Thomas Krug
Mechanic Name
James DeBell
James DeBell
Relief Valve Pressure
Slide
15
15
Governor Rope Pull
230/1100
230/1100
Door Closing Force
18
18
External ID
f591e631-d31b-4653-b234-2f048cc04742
f591e631-d31b-4653-b234-2f048cc04742
Location
Fashion Square Lofts
1307 Washington Ave, St. Louis, MO
Phone: (314) 621-6262
1307 Washington Ave, St. Louis, MO
Phone: (314) 621-6262
Owner
Attn: Fashion Square Lofts
Fashion Square Lofts LLC
4439 Old Alton Rd, Granite City, IL 62040
Phone: (314) 621-9292
Fashion Square Lofts LLC
4439 Old Alton Rd, Granite City, IL 62040
Phone: (314) 621-9292
Billing
Attn: Fashion Square Lofts
Fashion Square Lofts LLC
1307 Washington Ave, St. Louis, MO 63103
Phone: (314) 621-9292
Email: matt@mbdstl.com
Fashion Square Lofts LLC
1307 Washington Ave, St. Louis, MO 63103
Phone: (314) 621-9292
Email: matt@mbdstl.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | All the on site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. | 1/12/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 1/12/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | No | No | An ABC type fire extinguisher with a current test tag shall be mounted convenient to the machine room door. | 1/12/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.1 - Access to machine space | 8.11.2.1.2(a) | No | No | The machine room shall have a self-closing and self-locking door and shall be operable from the interior space without the use of a key. | 1/12/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | The in car emergency telephone shall be operational. | 2/28/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.20 - Governor rope | 2.18.5 | No | No | The governor rope shall be tagged. | 2/28/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.11 Periodic Inspection and Test. | Yes | No | 8.11.2.1.2(gg) - Access to the winding drum safety shall be restored, and the safeties shall be tested with no load in the car. The means of access has been blocked by a new ceramic tile floor. The car/counterweight balance shall be verified and adjusted to the manufacturers specifications. | 2/28/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone fails to establish two way communication | 3/8/2022 |
| A17.1-2016 : Elevators | 2.29 - Car and counterweight safeties | 8.6.4.19.2 | Yes | Yes | Unable to perform annual test on car safeties. Flooring installed in car preventing access to wind up safety drum | 3/8/2022 |
| A17.1-2016 : Elevators | 3.28 - Counterweight and counterweight buffer | 8.11.2.1.3(m) | No | No | Replace deteriorated roller on the bottom left of the counter weight frame | 1/12/2026 |
| A17.1-2016 : Elevators | 3.22 - Wire rope fastening and hitch plate | 8.6.5.16.3 | Yes | No | Replace broken spring on counter weight rope hitch plate fastening | 2/27/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | Yes | No | Replace broken spring on the counter weight rope shackle rod. | 7/8/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency Phone in car fails to establish two-way communication | 7/8/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Replace the worn counter weight roller on the top left side of the counter weight | 1/12/2026 |