Inspection
Inspection Details
Equipment ID
9752
9752
Inspection Date
3/24/2023
3/24/2023
Inspection Type
Reinspection
Reinspection
Inspector Name
Michael Ledden
Michael Ledden
Mechanic Name
David Howerton
David Howerton
Relief Valve Pressure
NA
NA
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
NA
NA
External ID
340c49f0-643e-4b59-bf3f-bbae17d6056b
340c49f0-643e-4b59-bf3f-bbae17d6056b
Location
Del Monte Apartments
5622 DELMAR BLVD, SAINT LOUIS, MO
Phone: (314) 369-9441
5622 DELMAR BLVD, SAINT LOUIS, MO
Phone: (314) 369-9441
Owner
Attn: Alex Oliver
Del Monte Apartments
5622 Delmar Blvd, St. Louis, MO 63112
Phone: (314) 369-9441
Alt Phone: (314) 221-3879
Email: alex@opstl.com
Del Monte Apartments
5622 Delmar Blvd, St. Louis, MO 63112
Phone: (314) 369-9441
Alt Phone: (314) 221-3879
Email: alex@opstl.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | Yes | No | Repair inoperative emergency lights. | 9/24/2019 |
| conversion | conversion | n/a | No | No | Jack head is above the pump unit. Install pressure switch. | 2/24/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone does not work. | 3/1/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.5 - Car lighting and receptacles | 8.6.4.15 Emergency Lighting | Yes | No | Emergency light does not work. | 3/1/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.35 - Supply Line and Shutoff Valve | 3.19 | No | No | Install shut off valve in the machine room. | 2/24/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.37 - Pressure Switch | 8.11.3.2.5 Pressure Switch (Re-Inspection) | Yes | No | Jack head is above the pump unit. Install pressure switch. | 3/1/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.2 - Car top light and outlet | 8.11.2.1.3(b) | No | No | Car top light does not work. | 2/24/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Handrails need to be installed on top of car. 1 ft. gap between car top and back of hoistway. Side is open to other car. | 2/24/2020 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Pit needs to be cleaned. | 2/24/2020 |
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | Yes | Yes | Fire jewel not working. | 3/1/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | Yes | No | Machine room door shall be self locking and self closing. | 3/1/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)5 | Yes | No | Install pit ladder and platform to work on cylinder head. | 3/1/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.3 - Lighting and receptacles | 8.11.3.1.2(c) | No | No | Lighting in machine room is on a motion sensor in the hallway. Light needs to be on its own circuit. | 8/1/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.17 - Door and gate equipment | 8.6.4.13.1(l) door restrictors | Yes | Yes | Door restrictor does not work. Did not red tag. | 7/30/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.3 Guards Between Adjacent Pits | No | No | Pit ladder needs to be mounted to the wall and not a free standing ladder. | 8/1/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | The pit shall be kept clean. Clean the pit. | 4/7/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 4/7/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 2.27.1.1.5 Battery Backup Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | The in car emergency telephone shall be operational on normal power and battery back-up. | 3/24/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)5 | No | No | The pit shall have a permanently installed ladder. (Currently folding ladder) | 4/7/2026 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 4/7/2026 |
| MO Minimum : Elevators | (I) - Pits | (I)5 | Yes | No | A permanent code compliant pit ladder shall be installed. (Repeat Violation) Re-Inspection now required. | 10/18/2024 |
| MO Minimum : Elevators | (I) - Pits | (I)5 | Yes | No | A permanent code compliant pit ladder shall be installed. (Repeat Violation) Re-Inspection still required and if not compliant possible red tag to be issued. | 12/20/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Up to date operating certificate required in the machine room. | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | Pit shall be kept clean and dry. (full of water) | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.4 Access to Pit | No | No | Walk in put door shall be locked at all times. | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.7 Firefighters' Emergency Operation: Operating Procedures | No | No | Fire service moduels shall be covered |