Inspection
Inspection Details
Equipment ID
7905
7905
Inspection Date
3/28/2023
3/28/2023
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Robert Kehm
Robert Kehm
Mechanic Name
Ross Colligan
Ross Colligan
Relief Valve Pressure
NA
NA
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
Swing Doors
Swing Doors
External ID
76d08697-4c88-4633-aaeb-8c2fadc2a4c6
76d08697-4c88-4633-aaeb-8c2fadc2a4c6
Location
Siro OP Royal Oak, LLC
4960 Laclede Ave, St. Louis, MO
Phone: (000) 000-0000
4960 Laclede Ave, St. Louis, MO
Phone: (000) 000-0000
Owner
Attn: Royals Oak
Siro OP Royal Oak, LLC
4960 Laclede Ave, St. Louis, MO 63108
Phone: (000) 000-0000
Email: Richard.Woolard@reachltc.com
Siro OP Royal Oak, LLC
4960 Laclede Ave, St. Louis, MO 63108
Phone: (000) 000-0000
Email: Richard.Woolard@reachltc.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | Properly guard the pit light. | 5/12/2023 | ||
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)3 | The car top shall have a code compliant emergency exit. | 5/12/2023 | ||
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)2 | Re-socket hoist ropes on drum machine per A17.1 - 1996 Rule 1206.3 | 5/12/2023 | ||
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)3 | Car top shall have a code compliant emergency exit. | 5/12/2023 | ||
| MO Minimum : Elevators | (I) - Pits | (I)1 | The pit shall be kept clean. Clean the pit. | 5/12/2023 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | The machine room shall be cleaned. | 5/12/2023 | ||
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)2 | Re-socket hoist ropes on drum machine per A17.1 - 1996 Rule 1206.3 | 5/12/2023 | ||
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)3 | Car top shall have a code compliant emergency exit. | 5/12/2023 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.2(d) On-Site Documentation (Written Procedures for Evacuation and Cleaning) | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. Evacuation procedures are missing. (This item is for notification purposes for future violation in 2022) | 5/12/2023 | ||
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)2 | Wire ropes on drum-type machines shall be re-socketed in compliance with ASME A17.1 1996 edition, Rule 1206.3. | 5/12/2023 | ||
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | The test is incomplete. The following testing items remain: pull out/pull thru of governor, governor switch and jaw, governor full load test of car safeties, buffer and counterweight buffer test. | 11/22/2021 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.2(d) On-Site Documentation (Written Procedures for Evacuation and Cleaning) | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. Evacuation procedures are missing. | 5/12/2023 | ||
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)2 | Wire ropes on drum-type machines shall be re-socketed in compliance with ASME A17.1 1996 edition, Rule 1206.3. | 5/12/2023 |