Inspection
Inspection Details
Equipment ID
3911
3911
Inspection Date
4/14/2023
4/14/2023
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Raymond Stidham
Raymond Stidham
Mechanic Name
Steve Wiseman
Steve Wiseman
Relief Valve Pressure
Slide
Stopped Level
Stopped Level
Governor Rope Pull
N/A
N/A
Door Closing Force
23
23
External ID
b439f567-a9bb-4ffb-8dfa-bc8788b419a5
b439f567-a9bb-4ffb-8dfa-bc8788b419a5
Location
Shepherd of the Hills Inspiration Tower
5586 W 76 Country Blvd, Branson, MO
Phone: (417) 773-1555
5586 W 76 Country Blvd, Branson, MO
Phone: (417) 773-1555
Owner
Attn: Shepherd of the Hills
Shepherd of the Hills
5586 W 76 Country Blvd, Branson, MO 65616
Phone: (000) 000-0000
Shepherd of the Hills
5586 W 76 Country Blvd, Branson, MO 65616
Phone: (000) 000-0000
Billing
Attn: Shepard of the Hills
Jeffrey D Johnson
5586 W 76 Country Blvd, Branson, MO 65616
Phone: (000) 000-0000
Email: sbraden@oldmatt.com
Jeffrey D Johnson
5586 W 76 Country Blvd, Branson, MO 65616
Phone: (000) 000-0000
Email: sbraden@oldmatt.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Replace the burnt out lights in the machine room | 2/7/2020 |
| conversion | conversion | n/a | No | No | Replace the bad light switch in the stairwell leading to the machine room. | 2/7/2020 |
| conversion | conversion | n/a | No | No | Patch the big hole cut into the machine room ceiling | 2/7/2020 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Remove all the stored material and equipment from the elevator machine room that does not relate to the operatin of the elevator. | 2/7/2020 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Repair or replace the emergency phone as it has no dial tone. | 10/11/2019 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Replace the burnt out light tubes in the machine room to provide sufficent lighting around the controllers. | 2/7/2020 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Obtain and display a current state operating certificate in the machine room | 2/7/2020 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Repair the emergency phone as the incoming line is dead | 7/24/2020 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Obtain and display a current state operating certificate in the machine room | 6/10/2020 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Remove all the stored material that is not related to the operating of the elevator from the machine room | 6/10/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Repair the holes in the machine room ceiling and the stairway walls. | 8/30/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Repair or replace the burnt out lights in the machine room | 8/30/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Repair the spaulding concrete in the hoistway back wall nearing the top floor | 8/30/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.9 Cleaning of Top of Cars | No | No | Clean up the oil from the car top. | 7/15/2023 |