Inspection
Inspection Details
Equipment ID
14387
14387
Inspection Date
2/28/2023
2/28/2023
Inspection Type
Reinspection
Reinspection
Inspector Name
Robert Kehm
Robert Kehm
Mechanic Name
David Howerton
David Howerton
Relief Valve Pressure
NA
NA
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
NA
NA
External ID
9f5abc9a-e840-4275-8d4e-973f787f0ba5
9f5abc9a-e840-4275-8d4e-973f787f0ba5
Location
Westmoreland Apartments
245 Union Blvd, St. Louis, MO
Phone: (000) 000-0000
245 Union Blvd, St. Louis, MO
Phone: (000) 000-0000
Owner
Attn: Accounts Payable
275 on the Park
11766 Wilshire Blvd, Ste 325, Los Angeles, CA 90025
Phone: (281) 888-0832
275 on the Park
11766 Wilshire Blvd, Ste 325, Los Angeles, CA 90025
Phone: (281) 888-0832
Billing
Attn: Accounts Payable
275 on the Park - Annex
10330-DD Lake Rd, Houston, TX 77070
Phone: (281) 888-0832
Email: AP@unified-residential.com
275 on the Park - Annex
10330-DD Lake Rd, Houston, TX 77070
Phone: (281) 888-0832
Email: AP@unified-residential.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | x | Car door restrictor shall work. | 10/19/2018 | |
| conversion | conversion | conversion - reinspect | x | In cab emergency telephone shall work. | 10/19/2018 | |
| A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1001.2(b)(7) | The fire extinguisher the machine room is expired and shall be replaced by a current testing fire extinguisher. | |||
| A17.1-1996 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 1001.2(a)(18) | x | Make the door restrictor operational. | 5/14/2019 | |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | In cab emergency telephone shall work. | 5/14/2019 | |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 306.11 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | In car emergency telephone shall work. | 10/25/2019 | |
| A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1001.2(b)(7) | The fire extinguisher in the machine room is expired. A current tested ABC type fire extinguisher shall be kept in the machine room. | |||
| A17.1-1996 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 1001.2(a)(18) | x | The door restrictor shall be operational. | 2/23/2021 | |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | The in car emergency telephone shall be operational. | 2/23/2021 | |
| A17.1-1996 : Elevators | 2.1 - Access to machine space | 1001.2(b)(1) | The elevator machine room door shall be self-locking and self-closing and shall only be accessible to authorized personnel. | |||
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | The pit shall be kept clean. Clean the pit. | |||
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | The pit lighting shall be operational. | |||
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | Provide a code compliant MCP including onsite documents. | |||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.9 Cleaning of Top of Cars | The car top shall be cleaned. | |||
| A17.1-1996 : Elevators | 1.12 - Car enclosure | 1001.2(a)(12) | Replace the missing handrails in the elevator. | |||
| A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1001.2(b)(7) | A current tested & tagged ABC type fire extinguisher shall be provided in the elevator machine room. | |||
| A17.1-1996 : Elevators | 2.6 - Ventilation | 1001.2(b)(6) | The machine room ventilation shall be operational. | |||
| A17.1-1996 : Elevators | 2.5 - Housekeeping | 1001.2(b)(5) | Articles or materials not necessary for the maintenance or operation of the elevator shall not be stored in the machine room. | |||
| A17.1-1996 : Elevators | 1.3 - Operating control devices | 1001.2(a)(3) | All lights on the car operating panel shall be operational. | |||
| A17.1-1996 : Elevators | 1.12 - Car enclosure | 1001.2(a)(12) | Electrical devices in the car enclosure shall have covers installed. | |||
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (2)(C) Re-Inspection Required to Enforce. | x | The machine room door shall be self-closing, self-locking and shall be operable from the interior space without the use of a key. Note: There is no machine room door at all. | 4/14/2022 | |
| A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 1206.7 | A record of findings for firefighters' service operation required by 8.6.11.1 with identification of the person(s) that performed the operation shall be available on-site. | |||
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | |||
| A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1001.2(b)(7) | An ABC fire extinguisher with a current test tag shall be mounted in the machine room located convenient to the access door. Note: The test tag is expired. | |||
| A17.1-1996 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 111.5 Restricted Opening of Hall/Car Doors | x | The means to restrict opening of the car door shall be operational. | 4/14/2022 | |
| A17.1-1996 : Elevators | 1.15 - sign and operating device symbols | 1001.2(a)(15) | The car identification number shall be painted on, engraved, or securely attached to the car operating panel and shall be a minimum of 1/2" in height. | |||
| A17.1-1996 : Elevators | 1.3 - Operating control devices | 1001.2(a)(3) | The car operating panel car call indicator lights shall all be functional. | |||
| A17.1-1996 : Elevators | 1.12 - Car enclosure | 1001.2(a)(12) | The exposed wiring inside the fixture on the back wall of the elevator cab interior shall be enclosed. | |||
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) | x | The in car emergency lighting shall be operational. | 4/14/2022 | |
| A17.1-1996 : Elevators | 2.5 - Housekeeping | 1206.2b (Clean Machine Room) | Equipment in the machine room not being used in conjunction with the function or use of the elevator shall be removed. | |||
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | The safeties shall be tested as required by A17.2, item 2.29. Note: Winding drum safety access is presently covered by glued on flooring. | 4/14/2022 | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (2)(C) Re-Inspection Required to Enforce. | x | The machine room door shall be self-closing, self-locking and shall be operable from the interior space without the use of a key. Note: There is no machine room door at all. | 9/14/2023 | |
| A17.1-1996 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 111.5 Restricted Opening of Hall/Car Doors | x | The means to restrict opening of the car door shall be operational. | 9/14/2023 | |
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) | x | The in car emergency lighting shall be operational. | 9/14/2023 | |
| A17.1-2016 : Elevators | 4.1 - Car platform guard | 2.15.9 | x | Platform guard shall not be less than 48". Pit depth results in need of a retractable guard or variance approved by State board. If variance is not approved at next board meeting, unit shall be removed from service until proper guard is installed. | 10/25/2023 | |
| A17.1-1996 : Elevators | 1.17 - Standby power operation | 211.2 | x | Elevators that are equipped to operate on emergency power shall be tested with no load in the car, operating on emergency power. All cars to be tested. | 11/26/2024 | |
| A17.1-1996 : Elevators | 1.17 - Standby power operation | 211.2 | x | Emergency power testing could not be completed due to failure of auxiliary generator to operate. Take corrective action and re-test. | 1/13/2025 |