Inspection
Inspection Details
Equipment ID
7828
7828
Inspection Date
4/24/2023
4/24/2023
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Sean Carmody
Sean Carmody
Mechanic Name
Brant Willtrout
Brant Willtrout
Relief Valve Pressure
NA
NA
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
28
28
External ID
815197b9-2198-4cab-bac8-198991cbb4f4
815197b9-2198-4cab-bac8-198991cbb4f4
Location
Center for Interventional Pain Mgmt
5203 Chippewa St, St. Louis, MO
Phone: (314) 852-5500
5203 Chippewa St, St. Louis, MO
Phone: (314) 852-5500
Owner
Attn: Gurpreet S Padda, MD
Gurpreet S Padda, MD
5203 Chippewa St, Ste 301, St. Louis, MO 63109
Phone: (000) 000-0000
Gurpreet S Padda, MD
5203 Chippewa St, Ste 301, St. Louis, MO 63109
Phone: (000) 000-0000
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)1 | Install capacity plate in car | |||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | Service fire extingusher in machine room | |||
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Post current state certificate in machine room | |||
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | A permanent lighting fixture shall be provided in all pits to provide an illumination of not less than five (5) foot-candles at the pit floor. | |||
| MO Minimum : Elevators | (I) - Pits | (I)1 | The pit shall be kept clean and dry. The pit shall be cleaned. | |||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | Lighting in the machine room shall be not less than ten (10) foot-candles at floor level. | |||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | |||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | x | The in car emergency telephone shall be operational. | 1/27/2022 | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | The elevator broke down in the middle of the annual inspection and category 5 test. All category 5 testing items still remain and shall be witnessed. | 1/27/2022 | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | Lighting in the machine room shall be not less than ten (10) foot-candles at floor level. | |||
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | x | The in car emergency telephone shall be operational. | 2/23/2022 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | A current tested & tagged ABC type fire extinguisher shall be provided in the elevator machine room. | |||
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | A permanent lighting fixture shall be provided in all pits to provide an illumination of not less than five (5) foot-candles at the pit floor. | |||
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | x | The in car emergency telephone shall be operational. | 4/24/2023 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | A current tested & tagged ABC type fire extinguisher shall be provided in the elevator machine room. | |||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | Machine room door shall be self-closing and self-locking. | |||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | Machine room lighting shall be not less than 10 foot-candles at the floor. | |||
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)3 | The top of car emergency exit shall only be operable from the top of the car. | |||
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | Pit shall have code compliant lighting. | |||
| MO Minimum : Elevators | (I) - Pits | (I)1 | The pit shall be kept clean. Clean the pit. | |||
| MO Minimum : Elevators | (F) - Electrical Switches | (F)1 | x | Car shall have emergency stop switch. | 4/24/2023 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. Fire service check charts are not current, Evacuation procedures and maintenance chart are missing. | |||
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | x | The pit light switch shall be accessible from the pit door and code compliant pit lighting shall be provided. Multi-year violation. Re-Inspection required. | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | x | No fire extinguisher in machine room. A current tested and tagged ABC type fire extinguisher shall be provided in the machine room. Multi-year violation. Re-Inspection required. | ||
| MO Minimum : Elevators | (F) - Electrical Switches | (F)1 | x | Car shall have emergency stop switch. (Violation from prior inspection needs to be verified as corrected) | ||
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)3 | x | The top of car emergency exit shall only be operable from the top of the car. (Violation from prior inspection needs to be verified as corrected) |