Inspection
Inspection Details
Equipment ID
12670
12670
Inspection Date
3/24/2023
3/24/2023
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Mitchell McNeely
Mitchell McNeely
Mechanic Name
Richard King
Richard King
Relief Valve Pressure
Na
Na
Slide
Na
Na
Governor Rope Pull
Na
Na
Door Closing Force
Na
Na
External ID
d05c8bfb-380c-434c-a9d0-20dbc2744fec
d05c8bfb-380c-434c-a9d0-20dbc2744fec
Location
West County Center
44 W County Ctr, Des Peres, MO
Phone: (314) 288-2020
44 W County Ctr, Des Peres, MO
Phone: (314) 288-2020
Owner
Attn: Andrew Goldacker
CBL Properties/West County Center
80 W County Center, Des Peres, MO 63131
Phone: (314) 288-2026
Alt Phone: (314) 409-8204
Email: andrew.goldacker@cblproperties.com
CBL Properties/West County Center
80 W County Center, Des Peres, MO 63131
Phone: (314) 288-2026
Alt Phone: (314) 409-8204
Email: andrew.goldacker@cblproperties.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Repair Demarcation lights | 10/7/2019 |
| conversion | conversion | conversion - reinspect | Yes | No | Complete Annual Test-step indecing-within 30 days | 7/30/2018 |
| A17.1-1996 : Escalators | 7.5 - Lighting | 806.2 | No | No | Upper and lower demarcation lights are not working. Repair | 10/7/2019 |
| A17.1-1996 : Escalators | 8.12 - Steps, step chains, and trusses | 801.1 | No | No | Step chain clearances do not meet requirement. RED TAGGED | 10/7/2019 |
| A17.1-1996 : Escalators | 8.12 - Steps, step chains, and trusses | 802.11 | No | No | Entire truss needs to be cleaned out. | 10/7/2019 |
| A17.1-1996 : Escalators | 8.2 - Stop switch | 805.3e | No | No | Upper level stop switch buzzer is not working. | 10/7/2019 |
| A17.1-1996 : Escalators | 7.5 - Lighting | 1009.2d | No | No | Demarcation lights not working on both top and bottom. | 12/21/2020 |
| A17.1-1996 : Escalators | 7.3 - Handrails | 802.4 | No | No | Left handrail needs to be replaced. | 12/21/2020 |
| A17.1-1996 : Escalators | 7.10 - Operating and safety devices | 805.3a | No | No | Stop switch buzzer on top not working. | 12/21/2020 |
| A17.1-1996 : Escalators | 7.5 - Lighting | 805.7 | No | No | Demarcation light not working at bottom egress | 11/25/2019 |
| A17.1-1996 : Escalators | 7.5 - Lighting | 805.7 | No | No | Lower demarcation light is out | 12/7/2022 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Step indexing & comb plate impact devices need testing. Re-inspection required | 3/24/2023 |
| A17.1-2016 : Elevators | 7.3 - Handrails | 8.6.8.1 | No | No | Left handrail has a crack in it creating a pinching hazard. Replace handrail | 11/12/2025 |
| A17.1-1996 : Escalators | 8.12 - Steps, step chains, and trusses | 802.8 | No | No | Clean down escalator truss | 8/10/2026 |