Inspection
Inspection Details
Equipment ID
22449
22449
Inspection Date
5/23/2023
5/23/2023
Inspection Type
Reinspection
Reinspection
Inspector Name
Michael Gallaher
Michael Gallaher
Mechanic Name
James DeBell
James DeBell
Relief Valve Pressure
na
na
Slide
na
na
Governor Rope Pull
na
na
Door Closing Force
na
na
External ID
eb360e5c-4695-4dc3-9161-5e49cdae9f78
eb360e5c-4695-4dc3-9161-5e49cdae9f78
Location
IKEA Property
1 Ikea Way, St. Louis, MO
Phone: (314) 721-0410
1 Ikea Way, St. Louis, MO
Phone: (314) 721-0410
Owner
Attn: IKEA Property
IKEA Property
1 Ikea Way, St. Louis, MO 63110
Phone: (000) 000-0000
Email: dl.site.area.prep.410.us@ingka.com
IKEA Property
1 Ikea Way, St. Louis, MO 63110
Phone: (000) 000-0000
Email: dl.site.area.prep.410.us@ingka.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.17 - Step/skirt clearances, panels, and performance index | 6.1.3.3.5 | No | No | Step indexing could not be completed due to out of calibration equipment. Reinspection Required. | 11/26/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 8.1 - Machinery space access, lighting, receptacle, and condition | 8.6.8.13 | No | No | Clean escalator pit. | 1/23/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.5 - Lighting | 8.6.11.5(i) Demarcation Lighting (Re-Inspect) | Yes | No | Upper demarcation lights not working | 12/17/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.17 - Step/skirt clearances, panels, and performance index | 6.1.3.3.9 Step/Skirt Performance Index | Yes | No | Unit failed indexing,repair as needed. | 12/17/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.19 - Maintenance records | 8.6.1.4 | No | No | Provide MCP | 1/23/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.7 - Combplate and comb step impact device | 6.1.6.3.13 | Yes | No | Comb plate impact switches could not be tested due to comb plate screws being stripped out, repair and perform comb plate impact switch tests. Re-inspection required | 5/23/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 8.1 - Machinery space access, lighting, receptacle, and condition | 8.6.8.13 | No | No | Need to clean dirt & debris from escalator pits | 1/23/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 8.1 - Machinery space access, lighting, receptacle, and condition | 8.6.1.6.3 | No | No | Provide electrical prints for escalator | 1/23/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.5 - Lighting | 8.6.11.5(i) Demarcation Lighting (Re-Inspect) | Yes | No | Repair step demarcation lights at both landings. Re-inspection required | 8/14/2025 |
| A17.1-2016 : Elevators | 7.5 - Lighting | 6.1.7.2 | No | No | Demarcation Light not working at top or bottom. | 1/23/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 8.1 - Machinery space access, lighting, receptacle, and condition | 8.11.4.2.1 (Re-Inspection) | Yes | No | Escalator truss shall get a clean down |