Inspection
Inspection Details
Equipment ID
19743
19743
Inspection Date
6/23/2023
6/23/2023
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
David Harris
David Harris
Mechanic Name
Relief Valve Pressure
Slide
0-3
0-3
Governor Rope Pull
na
na
Door Closing Force
24
24
External ID
7f75fdb3-3249-431f-b188-0ad52dd6f5bd
7f75fdb3-3249-431f-b188-0ad52dd6f5bd
Location
Camden on the Lake
2359 BITTERSWEET RD, LAKE OZARK, MO
Phone: (573) 365-5620
2359 BITTERSWEET RD, LAKE OZARK, MO
Phone: (573) 365-5620
Owner
Camden on the Lake
2359 BITTERSWEET RD, LAKE OZARK, MO 65049-7008
2359 BITTERSWEET RD, LAKE OZARK, MO 65049-7008
Billing
Attn: Camden on the Lake
2359 BITTERSWEET RD, LAKE OZARK, MO 65049-7008
2359 BITTERSWEET RD, LAKE OZARK, MO 65049-7008
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | phone not working | 8/29/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.11 Periodic Inspection and Test. | Yes | No | Inspection incomplete - Elevator was left shut down due to software issues and bad card. Fire service still needs to be tested as well as the entire category 5 test. | 11/8/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.3 - Lighting and receptacles | 2.7.5.1 Lighting | No | No | Machine room lights all shall work and have 10 fc of light. | 11/6/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.3 - Lighting and receptacles | 2.7.5.1 Lighting | No | No | A17.1S - 2005 - 2.7.9.1 - Machine/control spaces or rooms lighting need to be at least 19fc at the floor level. (Previously incorrectly cited as 10fc). Note: This unit is an MRL | 11/6/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.8 - Pipes, wiring, and ducts | 2.8.1 | No | No | A17.1S - 2005 - This unit is an MRL and there is no GFI receptacle or lights in overhead which is a machine space. | 11/6/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.8 - Pipes, wiring, and ducts | 2.8.1 | Yes | No | - This unit is an MRL and there is no GFI receptacle or lights in overhead which is a machine space. This was uncorrected from last year | 8/19/2025 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Machine room door not self locking | 11/6/2025 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency Phone Does not work | 8/19/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.8 - Pipes, wiring, and ducts | 2.8.1 | No | No | This unit is an MRL and there is no GFI receptacle or lights in overhead which is a machine space. | 11/6/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | Yes | No | repair/shorten runby | 8/27/2026 |