Inspection
Inspection Details
Equipment ID
16726
16726
Inspection Date
6/27/2023
6/27/2023
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Michael Bailey
Michael Bailey
Mechanic Name
Tom Worsham
Tom Worsham
Relief Valve Pressure
540
540
Slide
na
na
Governor Rope Pull
na
na
Door Closing Force
25
25
External ID
cf5aa1a5-b517-4d25-b993-aaff9ebe9d2e
cf5aa1a5-b517-4d25-b993-aaff9ebe9d2e
Location
All Star Dodge Chrysler Jeep
11503 Saint Charles Rock Rd, Bridgeton, MO
Phone: (314) 291-2050
11503 Saint Charles Rock Rd, Bridgeton, MO
Phone: (314) 291-2050
Owner
Attn: Jeff Ferguson
All Star Dodge Chrysler Jeep
11503 Saint Charles Rock Rd, Bridgeton, MO 63044
Phone: (314) 291-2050
Email: jeff@314allstar.com
All Star Dodge Chrysler Jeep
11503 Saint Charles Rock Rd, Bridgeton, MO 63044
Phone: (314) 291-2050
Email: jeff@314allstar.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 1206.2a (Pits and Hoistways) | No | No | Clean pit and empty oil recovery bucket. | 10/15/2020 |
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | Provide maintenance control program. | 10/15/2020 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone does not work. | 11/30/2021 |
| A17.1-1996 : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing (Re-Inspection) | Yes | No | Perform OSV testing within 30 days. Re-inspection required | 7/15/2022 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency two way communication does not work. Phone line shall be monitored 24/7 and be able to provide an accurate location. Repair and reinspect. Code 2.27.1 | 11/4/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.1 Examination and Maintenance | No | No | Hydraulic jack packings are leaking and need to be replaced | 7/22/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Elevator cab phone repeatedly went to a voicemall. Elevator cab phones shall go to authorized personnel to take appropriate action in case of an emergency. Re-inspection required | 7/22/2026 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Need to clean hydraulic fluid from elevator pit | 7/22/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.1 Examination and Maintenance | No | No | Hydraulic jack packings are leaing and need to be replaced. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | Yes | No | Elevator cab phone repeatedly went to a voicemall. Elevator cab phones shall go to authorized personnel to take appropriate action in case of an emergency. Re-inspection required | |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Need to clean hydraulic fluid from elevator pit. 5 - gallon buckets are full and overflowing into pit. |