Inspection
Inspection Details
Equipment ID
18745
18745
Inspection Date
6/14/2023
6/14/2023
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Thomas Sharp
Thomas Sharp
Mechanic Name
Tom Worsham
Tom Worsham
Relief Valve Pressure
5000
5000
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
18
18
External ID
70a9cc56-9b73-43c8-85f6-7e7e26eb57d9
70a9cc56-9b73-43c8-85f6-7e7e26eb57d9
Location
COVO
401 Pine St, St. Louis, MO
Phone: (314) 455-6313
401 Pine St, St. Louis, MO
Phone: (314) 455-6313
Owner
Attn: TechArtista Downtown LLC
TechArtista Downtown LLC
401 Pine St, St. Louis, MO 63102
Phone: (925) 683-8254
Email: alex@techartista.org
TechArtista Downtown LLC
401 Pine St, St. Louis, MO 63102
Phone: (925) 683-8254
Email: alex@techartista.org
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Repair emergency phone ( building not occupied) | 9/16/2019 |
| MO Minimum : Elevators | (A) - Hoistways | (A)6 | No | No | Repair broken door reopening device. | 9/16/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Repair inoperative emergency light. | 7/26/2019 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)9 Capacity Plate | No | No | Post capacity in the elevator cab. | 9/16/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Maintenance and test records shall be maintained. | 9/16/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone does not work. | 10/23/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Reassemble emergency light and replace bulb. | 10/23/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | A copy of the MCP shall be kept in the machine room for each elevator | 4/7/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Need a current fire extinguisher in machine room | 4/7/2026 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | No | Phase 2 operation is not properly functioning and shall be repaired for a reinspection. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | No | No | Door edge reopening device is inoperable and shall be repaired or replaced. |