Inspection
Inspection Details
Equipment ID
8773
8773
Inspection Date
7/5/2023
7/5/2023
Inspection Type
Special Inspection
Special Inspection
Inspector Name
Melvin Barks Jr.
Melvin Barks Jr.
Mechanic Name
Relief Valve Pressure
N/A
N/A
Slide
N/A
N/A
Governor Rope Pull
N/A
N/A
Door Closing Force
N/A
N/A
External ID
d6df5f33-409f-4570-a48d-90e1c09b8843
d6df5f33-409f-4570-a48d-90e1c09b8843
Location
Edgewater Point Office Bldg
1000 Edgewater Pt, Lake St. Louis, MO
Phone: (314) 239-4333
Email: tonyb@tbr-d.com
1000 Edgewater Pt, Lake St. Louis, MO
Phone: (314) 239-4333
Email: tonyb@tbr-d.com
Owner
Attn: St. Johns Bank & Trust
TBRD
2642 Hwy 109, Ste F, Wildwood, MO 63040
Phone: (000) 000-0000
TBRD
2642 Hwy 109, Ste F, Wildwood, MO 63040
Phone: (000) 000-0000
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Remove compressor from elevator Machine Room - Blocking entrance | 5/29/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | All water and gas conveying devices shall be separated from the elevator machine room | 5/29/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Machine room lighting shall be 10ft candles through out. Measured at the floor. | 5/29/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Remove cable equipment from the elevator machine room | 5/29/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.2 Oil Leakage Collection | No | No | Provide a 5gal maximum container in the pit to collect packing leakage | 5/29/2026 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | No | Connect fire alarm initiating devices to the elevator controller | 5/11/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Repair inoperative emergency phone | 5/11/2023 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)7 | No | No | Provide testing of shunt trip disconnect activated by the machine room heat detector | 5/29/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.1.6.3 Controllers ,Wiring and Wiring Diagrams | No | No | Provide current and up to date prints in the machine room | 5/29/2026 |
| MO Minimum : Elevators | (A) - Hoistways | (A)3 | No | No | Door closing device shall close door when the elevator is not at the landing | 5/29/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Fire extinguisher dated 2017. Provide a Fire extinguisher with a current service date | 5/29/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | Provide maintenance logs | 5/29/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.1 General Maintenance Requirements Documentation | No | No | Provide maintenance control program | 5/29/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Machine room door shall be self closing and self locking | 5/29/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Replace missing in car handrail | 5/29/2026 |
| MO Minimum : Elevators | 11 CSR 40-5.130 Variances | (2)(B) Variance Inspection | No | No | Required Variance Inspection required | 5/29/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Remove compressor from elevator Machine Room - Blocking entrance | 5/29/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | All water and gas conveying devices shall be separated from the elevator machine room | 5/29/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Machine room lighting shall be 10ft candles through out. Measured at the floor | 5/29/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Remove cable equipment from the elevator machine room | 5/29/2026 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | No | Connect fire alarm initiating devices to the elevator controller | 2/27/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)7 | No | No | Provide testing of shunt trip disconnect activated by the machine room heat detector | 5/29/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.1.6.3 Controllers ,Wiring and Wiring Diagrams | No | No | Provide current and up to date prints in the machine room | 5/29/2026 |
| MO Minimum : Elevators | (A) - Hoistways | (A)3 | No | No | Door closing device shall close door when the elevator is not at the landing | 5/29/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Fire extinguisher dated 2017. Provide a Fire extinguisher with a current service date | 5/29/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | Provide maintenance logs | 5/29/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.1 General Maintenance Requirements Documentation | No | No | Provide maintenance control program | 5/29/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Machine room door shall be self closing and self locking | 5/29/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Replacement Parts::Replace missing in car handrail | 5/29/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Need to replace missing handrail | 5/29/2026 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current operating certificate shall be displayed in the machine room | 5/29/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Remove cable equipment from the elevator machine room | 5/29/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)7 | No | No | Provide testing of shunt trip disconnect activated by the machine room heat detector | 5/29/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.2(a) On-Site Documentation (Up-to-Date Wiring Diagrams) | No | No | Provide up to date wiring diagrams in the machine room | 5/29/2026 |
| MO Minimum : Elevators | (A) - Hoistways | (A)3 | No | No | Door closing device at bottom landing shall close hoistway door when elevator is not at the landing | 5/29/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Fire extinguisher dated 2017. Provide a Fire extinguisher with a current service date | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current operating certificate shall be displayed in the machine room | 6/3/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Remove cable equipment from the elevator machine room | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)7 | No | No | Provide testing of shunt trip disconnect activated by the machine room heat detector | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.2(a) On-Site Documentation (Up-to-Date Wiring Diagrams) | No | No | Provide up to date wiring diagrams in the machine room |