Inspection
Inspection Details
Equipment ID
507
507
Inspection Date
7/12/2023
7/12/2023
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
James VanZant
James VanZant
Mechanic Name
Shaun Deckard
Shaun Deckard
Relief Valve Pressure
365
365
Slide
Governor Rope Pull
Door Closing Force
27/20
27/20
External ID
b27bd0fe-9404-48cf-9d78-df23d61dce7f
b27bd0fe-9404-48cf-9d78-df23d61dce7f
Location
The Oaks Apartments
321 Hamilton St, Neosho, MO
Phone: (417) 451-5303
Email: NHA4321@AOL.com
321 Hamilton St, Neosho, MO
Phone: (417) 451-5303
Email: NHA4321@AOL.com
Owner
Attn: Neosho Housing Authority
Neosho Housing Authority
321 Hamilton St, Neosho, MO 64850
Phone: (000) 000-0000
Email: DirectorNeoshoHousing@outlook.com
Neosho Housing Authority
321 Hamilton St, Neosho, MO 64850
Phone: (000) 000-0000
Email: DirectorNeoshoHousing@outlook.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | no current cdertificate | 11/8/2018 |
| conversion | conversion | conversion - reinspect | Yes | No | Telephone not working--reinspect required | 8/30/2018 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | 1.6 telephone does not work | 7/9/2019 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Current State Operating Permit shall be displayed in the Equipment Room in a non-combustible frame. | 8/6/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | 2-way communication device shall work and give proper location (REINSPECTION within 30 days) | 1/18/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | I(1)/106.1 Pit shall be kept dry. Investigate and repair water leak. | 8/6/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | 2-way communication device shall work and give proper location (REINSPECTION within 30 days) | 1/18/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | I(1)/106.1 Pit shall be kept dry. Investigate and repair water leak. (Pit dry 1/18/21) | 1/18/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | phone shall work | 10/22/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | No MCP onsite. | 10/14/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | phone shall work | 10/22/2021 |
| A17.1-2016 : Elevators | 1.6 - Car emergency signal | 2.27.1.1.6 Verification of Telephone Operability | Yes | No | 2.27.1.1.6(a)Emergency communications loss monitor shall work. (REINSPECTION REQUIRED) | 9/27/2022 |