Inspection
Inspection Details
Equipment ID
11324
11324
Inspection Date
6/5/2023
6/5/2023
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Michael Gallaher
Michael Gallaher
Mechanic Name
James DeBell
James DeBell
Relief Valve Pressure
560
560
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
24/26
24/26
External ID
bfd301b1-7913-4dc1-9d3d-f155eede4c15
bfd301b1-7913-4dc1-9d3d-f155eede4c15
Location
The Salvation Army Family Store
4121 Forest Park Ave, St. Louis, MO
Phone: (314) 535-2000
4121 Forest Park Ave, St. Louis, MO
Phone: (314) 535-2000
Owner
Attn: Salvation Army ARC
Salvation Army ARC
3949 Forest Park Ave, St. Louis, MO 63108
Phone: (000) 000-0000
Salvation Army ARC
3949 Forest Park Ave, St. Louis, MO 63108
Phone: (000) 000-0000
Billing
Attn: The Salvation Army Thrift Store
The Salvation Army Thrift Store
4121 Forest Park Ave, St. Louis, MO 63108
Phone: (000) 000-0000
The Salvation Army Thrift Store
4121 Forest Park Ave, St. Louis, MO 63108
Phone: (000) 000-0000
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Repair emergency light in car | 10/31/2025 |
| conversion | conversion | n/a | No | No | Post current State certification in machine room | 10/31/2025 |
| conversion | conversion | conversion - reinspect | Yes | No | Make phone in car operational | 8/3/2018 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Display current operating certificate in machine room. | 10/31/2025 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone line does not work. | 6/14/2022 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Phone in elevator cab does not work, need to repair phone line. Re-inspection required | 9/30/2022 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | Light shall work. Repair same. | 10/31/2025 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of current operating certficate needs to be properly displayed in the machine room. | 10/31/2025 |
| A17.1-2016 : Elevators | 1.17 - Standby power operation | 8.6.4.19.7 (Re-Inspection) | Yes | No | Emergency battery lowering shall work. Reinspection required within 30 days. | 6/10/2025 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Phone in elevator cab does not work. Repair phone (phone line has 54 volts in controller) Rule B-11, Missouri minimum. Rule 8.11.3.1(F) A17.2, 2014. Reinspect by 7/14/23 (30 days) | 6/10/2025 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current state operating certificate shall be displayed in the machine room | 10/31/2025 |
| A17.1-1996 : Elevators | 1.17 - Standby power operation | 1002.2g (Standby Power Operation) | Yes | No | Emergency battery lowering shall work. Re-inspection required | 10/31/2025 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Phone in the elevator cab does not work, needs repaired. Re-inspection required | 10/31/2025 |
| A17.1-2016 : Elevators | 2.1 - Access to machine space | 2.7.3.4 | No | No | Machine room door frame is damaged due to fire department breaking into machine room during entrapment call, need to repair door frame. Also provide key to unlock machine room door |