Inspection
Inspection Details
Equipment ID
14862
14862
Inspection Date
7/28/2023
7/28/2023
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Cynthia "CJ" Brady
Cynthia "CJ" Brady
Mechanic Name
David Howerton
David Howerton
Relief Valve Pressure
440
440
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
16
16
External ID
04c34b7c-f174-4fba-b65e-323ea0df9c0a
04c34b7c-f174-4fba-b65e-323ea0df9c0a
Location
Westchase Building
10845 Olive Blvd, Creve Coeur, MO
Phone: (314) 542-0777
10845 Olive Blvd, Creve Coeur, MO
Phone: (314) 542-0777
Owner
Attn: Tina Moser
Scott Properties
1065 Executive Pkwy Dr, Ste 300, Creve Coeur, MO 63141
Phone: (314) 542-0777
Email: tmoser@scottproperties.com
Scott Properties
1065 Executive Pkwy Dr, Ste 300, Creve Coeur, MO 63141
Phone: (314) 542-0777
Email: tmoser@scottproperties.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Oil Recovery Bucket Full, check seal. | 9/23/2019 |
| conversion | conversion | conversion - reinspect | Yes | No | Car will not stop at floor 2 and 3 on phase 2 fire service and returns to floor 1. | 8/2/2018 |
| conversion | conversion | n/a | No | No | Replace expired battery in door restrictor control box. | 9/23/2019 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)6 | No | No | In cab emergency lights shall work. | 9/23/2019 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | In cab emergency alarm bell shall work. | 10/3/2018 |
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | Yes | No | Door re-opening device (eye ray), sensitive to smoke, shall be overridden during Phase 1 and Phase 2 fire service operation. | 10/3/2018 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Display current state operating certificate. | 9/23/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 7/27/2021 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | No | There were no fire service keys to test fire service. Keys shall be kept on-site and fire service shall be tested. | 11/28/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | The in car emergency light shall be operational. | 11/28/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Car emergency light shall be operational. |