Inspection
Inspection Details
Equipment ID
12401
12401
Inspection Date
8/2/2023
8/2/2023
Inspection Type
Reinspection
Reinspection
Inspector Name
Jerry Eckhart
Jerry Eckhart
Mechanic Name
Roy Parker
Roy Parker
Relief Valve Pressure
NA
NA
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
NA
NA
External ID
a646ab31-5444-4dde-ab17-2dfe611cc8c3
a646ab31-5444-4dde-ab17-2dfe611cc8c3
Location
City of St. Ann
10405 Saint Charles Rock Rd, St. Ann, MO
Phone: (314) 428-8009
10405 Saint Charles Rock Rd, St. Ann, MO
Phone: (314) 428-8009
Owner
Attn: St. Ann, City of
St. Ann, City of
10405 Saint Charles Rock Rd, St. Ann, MO 63074
Phone: (000) 000-0000
Email: bvogel@stannmo.org
St. Ann, City of
10405 Saint Charles Rock Rd, St. Ann, MO 63074
Phone: (000) 000-0000
Email: bvogel@stannmo.org
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Pit shall be kept dry. | 10/28/2020 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Pit has oil & water covering floor | 7/27/2026 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone is not working. Re-inspection required | 7/5/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.2 Oil Leakage Collection | No | No | Scavenger pumps that do not record the amount of oil returned to the hydraulic tank shall not be installed in elevator pits. Install a maximum of a 5 gallon container in elevator pit to record oil loss | 7/27/2026 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing | No | No | OSV is due for full load test and tripping speed checked. On or before the next inspetion | 7/27/2026 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Phone in elevator cab does not work. Re-inspection required | 8/2/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Need to clean oil from elevator pit | 7/27/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) | Yes | No | Rear car door restrictor does not work, needs repaired. Re-inspection required | 8/2/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.2 Oil Leakage Collection | No | No | Scavenger pumps that do not record the amount of oil returned to the hydraulic tank shall not be installed in elevator pits. Install a maximum of a 5 gallon container in elevator pit to record oil loss | 7/27/2026 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Phone in elevator cab not working Reinspection required | 6/27/2024 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Clean oil from elevator pit | 7/27/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.2 Oil Leakage Collection | No | No | Scavenger pumps that do not record the amount of oil returned to the hydraulic tank shall not be installed in elevator pits. Install a maximum of a 5 gallon container in elevator pit to record oil loss | 7/27/2026 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone in cab is not working. Re-inspection required | 6/27/2024 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Need to clean oil from elevator pit | 7/27/2026 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Elevator pit has what appears to be water and/or oil in it. Pit shall be kept clean and dry | 7/27/2026 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency two way communication device does not operate. Repair and reinspect | 7/31/2025 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Elevator pit has what appears to be water and/or oil in it. Pit shall be kept clean and dry | 7/27/2026 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency two way communication phone does not operate. If not repaired in 14 days car will be red tagged and removed from service for consecutive years of violation | 7/27/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.2 Oil Leakage Collection | Yes | No | Scavenger pumps that do not record the amount of oil returned to the hydraulic tank shall not be installed in elevator pits. Install a maximum of a 5 gallon container in elevator pit to record oil loss | 7/27/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) | Yes | No | Door restrictor on the rear doo is inoperable | 7/27/2026 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Pit has oil & water covering floor. Pit shall be kept clean and dry | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.2 Oil Leakage Collection | No | No | Scavenger pumps that do not record the amount of oil returned to the hydraulic tank shall not be installed in elevator pits. Install a maximum of a 5 gallon container in elevator pit to record oil loss |