Inspection
Inspection Details
Equipment ID
19509
19509
Inspection Date
5/23/2023
5/23/2023
Inspection Type
Temporary Certificate Inspection
Temporary Certificate Inspection
Inspector Name
Cynthia "CJ" Brady
Cynthia "CJ" Brady
Mechanic Name
Raymond Gore
Raymond Gore
Relief Valve Pressure
NA
NA
Slide
TBD
TBD
Governor Rope Pull
TBD
TBD
Door Closing Force
18
18
External ID
bad94af1-8251-4522-9bac-928af7754173
bad94af1-8251-4522-9bac-928af7754173
Location
Trader's Building
801 N 2nd St, St. Louis, MO
Phone: (314) 421-2005
801 N 2nd St, St. Louis, MO
Phone: (314) 421-2005
Owner
Attn: Trader Building, LLC
Trader Building, LLC
701 N 1st St, Ste 102, St. Louis, MO 63102
Phone: (314) 260-9266
Email: invoices@advantesgrp.com
Trader Building, LLC
701 N 1st St, Ste 102, St. Louis, MO 63102
Phone: (314) 260-9266
Email: invoices@advantesgrp.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | This inspection was to allow temporary usage of the elevator. The temporary use inspection was stopped as the elevator would not pick the rated load. The 5 year testing required for the temporary usage inspection shall be completed. | 6/13/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | No | No | Detector edge shall work (not currently installed). | 2/13/2026 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | 2-WAY Communication device shall work and be Code Compliant. | 2/13/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Clearance between car door panel and the car entrance jamb exceeds 13mm(0.5in) (COP jamb) | 2/13/2026 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)1 | No | No | COP shall be securely attached to cab interior. Currently leaning against wall. | 2/13/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) | Yes | No | Car Door Restrictor shall work entire length of hoistway, when outside of door zones. (not currently installed) | 2/13/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Roof Access door has disconnected/broken “hold open” latch. Safety hazard. | 2/13/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Machine room door shall be self-closing and self-locking. | 2/13/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Machine room lighting needs to be repaired, 1 or more bulbs not working. | 2/13/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Machine Room shall have proper Fire Extinguisher and shall have current monthly/annual test tag. (Expired2016). | 2/13/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Top emergency exit electrical contact shall work. (Switch not installed, Required as of 2000.) | 2/13/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Top Emergence Exit shall be hinged or otherwise attached to the cartop(chain, etc) and properly secured (wingnut, etc) (currently not attached or bolted.) | |
| MO Minimum : Elevators | (A) - Hoistways | (A)1 | No | No | Hoistway doors have 2 escutcheon holes. Fill unused hole. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Remove unused/not required Heat detectors in Machine Room and Top of Hoistway orthey shall work properly. (no Sprinklers or Shunt). |