Inspection
Inspection Details
Equipment ID
21461
21461
Inspection Date
8/22/2023
8/22/2023
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
Mitchell McNeely
Mitchell McNeely
Mechanic Name
Thomas Kitzinger
Thomas Kitzinger
Relief Valve Pressure
500
500
Slide
Na
Na
Governor Rope Pull
Na
Na
Door Closing Force
23/22
23/22
External ID
236d8543-2af2-47f0-b733-fccc0af616fd
236d8543-2af2-47f0-b733-fccc0af616fd
Location
MX Movies
601 Washington Ave, St. Louis, MO
Phone: (314) 531-0400
601 Washington Ave, St. Louis, MO
Phone: (314) 531-0400
Owner
Attn: MX Movies LLC
MX Movies LLC
906 Olive St, St. Louis, MO 63101
Phone: (000) 000-0000
MX Movies LLC
906 Olive St, St. Louis, MO 63101
Phone: (000) 000-0000
Billing
Attn: MX Movies LLC
MX Movies LLC
8300 Eager Rd, Ste 601, St. Louis, MO 63144
Phone: (000) 000-0000
MX Movies LLC
8300 Eager Rd, Ste 601, St. Louis, MO 63144
Phone: (000) 000-0000
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.5 Illumination of Pits | No | No | Repair pit light. | 1/22/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | Written maintenance control program shall be kept on site for each elevator. | 11/10/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | Yes | Phone in elevator cab does not work. Alarm bell does not exist. Elevator removed from service. | 7/16/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.5 - Housekeeping | 8.6.4.7 Cleaning of Hoistways and Pits | No | No | Clean car top. | 11/10/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | Clean the pit. | 11/10/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.17 - Standby power operation | 3.26.10 (Auxiliary Power)(Re-Inspection) | Yes | No | Provide existing battery backup lowering unit to work properly. | 6/16/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | Lower hoistway jamb access halo ring is worn and unreadable, replace. | 11/10/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | Firefighters switch halo ring is worn and unreadable, replace. | 11/10/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | State operating certificate shall be displayed inside of elevator machine room. | 11/10/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.15 - sign and operating device symbols | 8.6.1.6.7 | No | No | Hoistway access switch halo is worn and unreadable, replace. | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.15 - sign and operating device symbols | 8.6.1.6.7 | No | No | Phase I switch halo is worn and unreadable, replace. |