Inspection
Inspection Details
Equipment ID
9134
9134
Inspection Date
8/14/2023
8/14/2023
Inspection Type
Major Alteration
Major Alteration
Inspector Name
Sean Carmody
Sean Carmody
Mechanic Name
Jake Brennan
Jake Brennan
Relief Valve Pressure
N/A
N/A
Slide
Instantaneous
Instantaneous
Governor Rope Pull
50/640
50/640
Door Closing Force
16
16
External ID
f5b654aa-3b46-4bf7-b7e9-41f267190184
f5b654aa-3b46-4bf7-b7e9-41f267190184
Location
St. Louis University High School
4970 Oakland Ave, St. Louis, MO
Phone: (314) 531-0330
4970 Oakland Ave, St. Louis, MO
Phone: (314) 531-0330
Owner
Attn: St. Louis University High School
St. Louis University High School
4970 Oakland Ave, St. Louis, MO 63110
Phone: (314) 531-0330
Email: mfischer@sluh.org
St. Louis University High School
4970 Oakland Ave, St. Louis, MO 63110
Phone: (314) 531-0330
Email: mfischer@sluh.org
Billing
Attn: St. Louis University High School
St. Louis University High School
4970 Oakland Ave, St. Louis, MO 63110
Phone: (314) 531-0330
Email: rfigge@sluh.org
St. Louis University High School
4970 Oakland Ave, St. Louis, MO 63110
Phone: (314) 531-0330
Email: rfigge@sluh.org
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 5/27/2026 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | The car safeties shall be tested with a full load. | 7/29/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)3 | No | No | The machine room floor shall cover the entire area of the machine room. Provide a cover or guard the unused machine room access opening. | 5/27/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | The machine room lighting shall be not less than 10 foot-candles at the floor. | 5/27/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | Provide hoist rope data tag. | 5/27/2026 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | Yes | No | Determine and correct cause of car not running while on car top inspection. | 7/29/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | The in car emergency telephone shall be operational. | 7/29/2021 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 5/27/2026 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current State Operating Permit shall be obtained and displayed in the Equipment Room | 6/4/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | Fire Service must be tested and properly documented monthly on Log Sheet located in the machine room. No logs present in Machine Room | |
| A17.1-2016 : Elevators | 3.8 - Top emergency exit | 8.11.2.1.3(l) | No | No | Top emergency exit shall be properly mounted to the cartop with either hinges or a chain tethered to the cartop to prevent accidental dropping of the hatch | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Where spring buffers, elastomeric buffers, or solid bumpers are used, the bottom runby shall be not less than 150 mm (6 in.), |