Inspection
Inspection Details
Equipment ID
15160
15160
Inspection Date
9/7/2023
9/7/2023
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Jerry Eckhart
Jerry Eckhart
Mechanic Name
Rodney Stevenson
Rodney Stevenson
Relief Valve Pressure
na
na
Slide
na
na
Governor Rope Pull
na
na
Door Closing Force
26
26
External ID
d1203a27-08cb-4f3a-adf3-9db676e428d5
d1203a27-08cb-4f3a-adf3-9db676e428d5
Location
The Saum & Hutcheson Arms Apartments
1919 S Grand Blvd, St. Louis, MO
Phone: (314) 685-1130
1919 S Grand Blvd, St. Louis, MO
Phone: (314) 685-1130
Owner
Attn: Revival STL Construction, LLC
Revival STL Construction, LLC
PO Box 46721, St. Louis, MO 63146
Phone: (314) 852-6755
Email: anshul@revivalstl.com
Revival STL Construction, LLC
PO Box 46721, St. Louis, MO 63146
Phone: (314) 852-6755
Email: anshul@revivalstl.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | Pit light shall work. | 3/22/2019 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | Provide adequate machine room lighting. | 3/22/2019 | ||
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | x | Phase 2 fire service shall work. | 10/4/2018 | |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | Unable to test the emergency lighting. | 3/22/2019 | ||
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | x | Phase 2 fire service shall work. | 11/13/2018 | |
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | x | x | Phase 2 fire service shall be operational. | 1/15/2020 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | Clean the pit. The pit shall be kept clean. | 11/1/2019 | ||
| MO Minimum : Elevators | (I) - Pits | (I)1 | Pit shall be kept clean. | 9/15/2020 | ||
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.1(a) | Provide MCP | 11/1/2021 | ||
| MO Minimum : Elevators | (S) - Fire Service | 211.7 Firefighters Operations/Signage | Post Phase I instructions near f/f switch | 11/1/2021 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | Phase II halo worn and unreadable | 11/1/2021 | ||
| MO Minimum : Elevators | (I) - Pits | (I)1 | Clean pit | 11/1/2021 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | Sheave seal worn and leaking, repair as needled | 11/1/2021 | ||
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | x | Need to replace defective hoist cables due to excessive rouge & diameter reduction. Re-inspection required in 90 days | 2/26/2025 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | Need to replace missing door gibbs on the 1st, 4th & 8th floors |