Inspection
Inspection Details
Equipment ID
5848
5848
Inspection Date
9/26/2017
9/26/2017
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Unknown Conversion
Unknown Conversion
Mechanic Name
Relief Valve Pressure
400
400
Slide
Governor Rope Pull
Door Closing Force
External ID
Location
Life Line Foods
2811 South 11th St, St. Joseph, MO
Phone: (816) 279-1651
2811 South 11th St, St. Joseph, MO
Phone: (816) 279-1651
Owner
Life Line Foods
2811 South 11th St, St. Joseph, MO 64503
2811 South 11th St, St. Joseph, MO 64503
Billing
Attn: Life Line Foods
2811 South 11th St, , MO 64503
2811 South 11th St, , MO 64503
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.2 Oil Leakage Collection | No | No | Remove scavenger pump from pit. | 10/3/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | No | No | Pull chain unlocking device covers do not lock shut. | 10/3/2023 |
| MO Minimum : Elevators | (O) - Existing Hydraulic Elevators | (O)4 | No | No | Elevator no load up 40 fpm and no load down 30 fpm.Crosshead data tag car speed 90fpm. | 10/3/2023 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | State operating certificate not displayed | 10/3/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.7 - Car door or gate | 8.11.2.1.1(g) | No | No | replace the vertical sliding car gate astragal, over half of the astragal is missing (8.6.4.13.1(g)) | 4/29/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.7 - Car door or gate | 8.11.2.1.1(g) | No | No | replace the vertical sliding car gate astragal, over half of the astragal is missing, and the safety cord for the reversal is broken and needs to be replaced (8.6.4.13.1(g)) | 4/29/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.7 - Car leveling and anticreep devices | 8.11.2.1.3(j) | No | No | all of the leveling vanes have been hit and are bent causing the elevator to not be level with the landing floor, repair all leveling vanes | 4/29/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 4.2 - Hoistway doors | 8.11.2.1.4(b) | Yes | No | Top landing hoistway door the bottom panel is missing half of the beveled guard | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.7 - Car leveling and anticreep devices | 2.26.1.6 | No | No | All of the leveling vanes have been hit and are bent, repair leveling vanes | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.3 - Lighting and receptacles | 2.7.5.1 | No | No | Machine room lighting required to have 10 foot candles of illumination at the floor |