Inspection
Inspection Details
Equipment ID
17299
17299
Inspection Date
9/29/2023
9/29/2023
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
David Folkert
David Folkert
Mechanic Name
Jason Stout
Jason Stout
Relief Valve Pressure
na
na
Slide
na
na
Governor Rope Pull
na
na
Door Closing Force
23
23
External ID
de7fba02-3376-41e0-b946-1eb8cf3e0748
de7fba02-3376-41e0-b946-1eb8cf3e0748
Location
Lofts at Landmark
210 N 4TH ST, SAINT JOSEPH, MO
Phone: (816) 232-5212
210 N 4TH ST, SAINT JOSEPH, MO
Phone: (816) 232-5212
Owner
Attn: Lofts at Landmark
Lofts at Landmark
210 N 4th St, St. Joseph, MO 64501
Phone: (816) 232-5212
Email: loftsatlandmark@fairwaymanagement.com
Lofts at Landmark
210 N 4th St, St. Joseph, MO 64501
Phone: (816) 232-5212
Email: loftsatlandmark@fairwaymanagement.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Post current state operating certficate inside machine room | 1/3/2024 | ||
| A17.1-1996 : Elevators | 2.8 - Pipes, wiring, and ducts | 102.1 | Electrical power feed for machine room air conditioner need tobe in conduit. | 1/3/2024 | ||
| A17.1-2016 : Elevators | 2.5 - Housekeeping | 8.6.4.8 Machine Room and Machinery Space | Remove debris and rubbish from machine room floor | 1/3/2024 | ||
| A17.1-2016 : Elevators | 1.6 - Car emergency signal | 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Emergency phone does not operate | 9/24/2021 | |
| A17.1-2016 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 8.6.4.19.16 | x | Car door restrictor does not function | 9/24/2021 | |
| A17.1-1996 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 1001.2(a)(18) | x | Car door restrictor does not function | 9/16/2022 | |
| A17.1-1996 : Elevators | 2.8 - Pipes, wiring, and ducts | 102.1 | Electrical supply wiring for machine room air conditioner needs to be in metal conduit. Remove 20 foot extension cord that runs across the machine room floor | 1/3/2024 | ||
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 306.11 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Emergency phone does not operate. | 9/16/2022 | |
| A17.1-1996 : Elevators | 2.1 - Access to machine space | 101.3d | Machine room access door needs to be self-locking and non-defeatable. | 1/3/2024 | ||
| A17.1-1996 : Elevators | 2.14 - Code data plate | 215 | Post code data plate on controller or disconnect. "ASME A17.1 1996" | 1/3/2024 | ||
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Post current state operating certificate inside the machine room. | 1/3/2024 | ||
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Emergency phone does not operate | 9/29/2023 | |
| A17.1-1996 : Elevators | 2.1 - Access to machine space | 101.3d | Machine room access door needs to be self-locking and non-defeatable | 1/3/2024 | ||
| A17.1-1996 : Elevators | 2.14 - Code data plate | 215 | Post code data plate on controller or disconnect | 1/3/2024 | ||
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | State operating certificate not displayed in machine room | 1/3/2024 | ||
| MO Minimum : Elevators | (I) - Pits | (I)1 | Debris in pit, clean. | 10/29/2024 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | Emergency phone not connecting. | 9/27/2025 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | Replace all worn counterweight rollers. | 10/29/2024 | ||
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | car phone not working |