Inspection
Inspection Details
Equipment ID
12664
12664
Inspection Date
10/10/2018
10/10/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Derek Rankin
Derek Rankin
Mechanic Name
Mark Brown
Mark Brown
Relief Valve Pressure
Slide
Governor Rope Pull
Door Closing Force
External ID
3b0dde0b-cb7e-4f48-8625-fc65de054e75
3b0dde0b-cb7e-4f48-8625-fc65de054e75
Location
West County Center
44 W COUNTY CTR, DES PERES, MO
44 W COUNTY CTR, DES PERES, MO
Owner
CBL Properties
2030 HAMILTON PLACE BLVD STE 500, CHATTANOOGA, TN 37421-6000
2030 HAMILTON PLACE BLVD STE 500, CHATTANOOGA, TN 37421-6000
Billing
Attn: West County Center
80 W COUNTY CTR, DES PERES, MO 63131-3701
80 W COUNTY CTR, DES PERES, MO 63131-3701
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Clean down truss | 10/10/2019 |
| A17.1-1996 : Escalators | 7.3 - Handrails | 802.2 | No | No | Left side handrail needs to be replaced. It has cracks in it. | 10/10/2019 |
| A17.1-1996 : Escalators | 8.12 - Steps, step chains, and trusses | 1206.6 | No | No | Entire truss needs to be cleaned out. | 10/10/2019 |
| A17.1-1996 : Escalators | 8.12 - Steps, step chains, and trusses | 802.7 | No | No | Replace broken step teeth as needed. | 10/10/2019 |
| A17.1-1996 : Escalators | 8.12 - Steps, step chains, and trusses | 802.8 | No | Yes | Step chain clearances do not meet requirements. | 10/10/2019 |
| A17.1-1996 : Escalators | 8.4 - Drive machine and brake | 804 | Yes | Yes | Brake does not meet minimum brake torque. | 10/10/2019 |
| A17.1-1996 : Escalators | 7.15 - Balustrades | 802.3 | No | No | Bottom deck guards are wrong height and distance from handrail. | 10/10/2019 |
| A17.1-1996 : Escalators | 7.3 - Handrails | 802.4 | No | No | Replace right handrail due to excessive wear. | 10/25/2019 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.13 Escalator Cleaning | No | No | Need to perform clean down of unit | 3/13/2026 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.7 Rollers, Tracks, and Chains | Yes | Yes | Unit has stress crack in lower end step track, Red-tagged, Re-inspection required | 3/13/2026 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.6 Steps | Yes | No | Two steps have broken nose pieces, replace same | 3/13/2026 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.1 Escalator Handrails | Yes | Yes | Left handrail has cracks / pinch points, replace same. Red-tagged, Re-inspection required | 3/13/2026 |
| Missouri Minimum : Escalators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Need to perform step indexing to complete inspection. Re-inspection required | 3/13/2026 |
| Missouri Minimum : Escalators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Need to perform testing of all comb impact devices to complete inspection. Re-inspection required | 3/13/2026 |
| A17.1-2016 : Elevators | 7.17 - Step/skirt clearances, panels, and performance index | 8.6.8.3.3 | Yes | No | Testing of the right side failed. |