Inspection
Inspection Details
Equipment ID
1886
1886
Inspection Date
9/20/2018
9/20/2018
Inspection Type
Reinspection
Reinspection
Inspector Name
John Ryan
John Ryan
Mechanic Name
Ryan Pace
Ryan Pace
Relief Valve Pressure
Slide
N/A
N/A
Governor Rope Pull
N/A
N/A
Door Closing Force
N/A
N/A
External ID
6f60ede6-f571-4eb5-a2a5-7a3050c099eb
6f60ede6-f571-4eb5-a2a5-7a3050c099eb
Location
Courtyard by Marriott
400 Broadway Street, CAPE GIRARDEAU, MO
Phone: (573) 579-1901
400 Broadway Street, CAPE GIRARDEAU, MO
Phone: (573) 579-1901
Owner
Attn: UNK
H & H Center Property, LLC
1610 N. Kingshighway, Ste 301, CAPE GIRARDEAU, MO 63701
Phone: (573) 579-1901
Email: patty.schaefer@maysoncapital.com
H & H Center Property, LLC
1610 N. Kingshighway, Ste 301, CAPE GIRARDEAU, MO 63701
Phone: (573) 579-1901
Email: patty.schaefer@maysoncapital.com
Billing
Same as Owner
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
conversion | conversion | conversion - reinspect | x | Complete fire service recall on smoke detectors, shunt trips, and heat detectors. | 9/20/2018 | |
conversion | conversion | conversion - reinspect | x | Label disconnects with feeder panel, location, number, and breaker numbers. | 9/20/2018 | |
conversion | conversion | conversion - reinspect | x | Seal all penetrations and voids in the hoistway. | 9/20/2018 | |
conversion | conversion | conversion - reinspect | x | Need to test emergency light. | 9/20/2018 | |
conversion | conversion | conversion - reinspect | x | Machine room railing system shall be completed. | 9/20/2018 | |
conversion | conversion | conversion - reinspect | x | Flooring in the cab shall be installed. | 9/20/2018 | |
conversion | conversion | conversion - reinspect | x | Need pit lighting, light switch, caution signage, and pit door signage. | 9/20/2018 | |
conversion | conversion | conversion - reinspect | x | A code compliant fire extinguisher is required in the machine room. | 9/20/2018 | |
conversion | conversion | conversion - reinspect | x | Need to test emergency alarm and phone. | 9/20/2018 | |
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.2-2.27.8 | x | x | All emergency fire service features shall be tested, including smoke detectors, heat detectors, and shunt trip disconnect. | 10/5/2018 |
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Post current state operating certificate. | 8/26/2020 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | Provide MCP. | 8/26/2020 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | The in car emergency telephone shall be operational. | 3/15/2021 | |
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | All the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 4/16/2021 |