Inspection
Inspection Details
Equipment ID
19162
19162
Inspection Date
10/4/2023
10/4/2023
Inspection Type
Major Alteration
Major Alteration
Inspector Name
Michael Ledden
Michael Ledden
Mechanic Name
Dustin Schmidt
Dustin Schmidt
Relief Valve Pressure
550
550
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
NA
NA
External ID
4e2b0e80-f104-4656-8864-68b4f52804f3
4e2b0e80-f104-4656-8864-68b4f52804f3
Location
Store Space - LO26 - St. Louis
725 N 23rd St, St. Louis, MO
Phone: (314) 231-6006
Email: 191STORESPACE@STORESPACE.COM
725 N 23rd St, St. Louis, MO
Phone: (314) 231-6006
Email: 191STORESPACE@STORESPACE.COM
Owner
Attn: Store Space
Store Space
330 E Crown Point Rd, Winter Garden, FL 34787
Phone: (000) 000-0000
Email: MCutting@storespace.com
Store Space
330 E Crown Point Rd, Winter Garden, FL 34787
Phone: (000) 000-0000
Email: MCutting@storespace.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Provide a permanent source of cab lighting. | 12/1/2021 |
| conversion | conversion | conversion - reinspect | Yes | No | Secure car top exit. | 10/11/2017 |
| conversion | conversion | conversion - reinspect | Yes | No | Repair hole in hoistway wall near 4th floor. | 10/11/2017 |
| conversion | conversion | conversion - reinspect | Yes | No | Repair or replace screening on cab wall. | 10/11/2017 |
| conversion | conversion | conversion - reinspect | Yes | No | Refasten back cab wall. | 10/11/2017 |
| conversion | conversion | conversion - reinspect | Yes | No | Repair hole in hoistway wall near 4th floor. | 8/20/2018 |
| conversion | conversion | conversion - reinspect | Yes | No | Refasten back cab wall. | 8/20/2018 |
| conversion | conversion | n/a | No | No | Provide a permanent source for cab lighting. | 12/1/2021 |
| conversion | conversion | conversion - reinspect | Yes | No | Repair or replace screening on cab wall. | 8/20/2018 |
| conversion | conversion | conversion - reinspect | Yes | No | Secure car top exit. | 8/20/2018 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.2 - Car top light and outlet | 8.11.2.1.3(b) | No | No | Repair car top light. | 12/1/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 4.2 - Hoistway doors | 8.11.2.1.4(b) | Yes | No | Repair door to sill clearance 1st and 4th floors. | 1/28/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 4.2 - Hoistway doors | 8.11.2.1.4(b) | Yes | No | Provide missing straps on hoistway doors | 1/29/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 4.5 - Access to Hoistway | 8.11.2.1.4(e) | No | No | Provide hoistway access to the top of car | 12/1/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.11.2.1.2(g) | No | No | Provide ABC rated fire Extinguisher in machine space | 12/1/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | Written maintenance control program shall be kept on site for each elevator. | 12/1/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 4.5 - Access to Hoistway | 8.11.2.1.4(e) | No | No | Access means shall be provided at one upper landing to permit access to the top of the car. | 12/1/2021 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing (Re-Inspect) | Yes | No | OSV is due for Cat 5 testing | 5/4/2022 |
| MO Minimum : Elevators | (F) - Electrical Switches | (F)1 | Yes | No | Bottom normal not working properly. Re-inspection required | 2/4/2025 |