Inspection
Inspection Details
Equipment ID
20481
20481
Inspection Date
10/23/2023
10/23/2023
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
James VanZant
James VanZant
Mechanic Name
Shaun Deckard
Shaun Deckard
Relief Valve Pressure
Slide
1
1
Governor Rope Pull
35/275
35/275
Door Closing Force
15/18
15/18
External ID
479245ea-30bd-4aaf-a247-d483be847355
479245ea-30bd-4aaf-a247-d483be847355
Location
Memorial Middle School
310 W 8th St, Joplin, MO
Phone: (417) 625-5300
Email: LishaHardy@joplinschools.org
310 W 8th St, Joplin, MO
Phone: (417) 625-5300
Email: LishaHardy@joplinschools.org
Owner
Attn: Joplin R-VIII School District
Joplin R-VIII School District
1717 E 15th St, Joplin, MO 64804
Phone: (417) 625-5300
Joplin R-VIII School District
1717 E 15th St, Joplin, MO 64804
Phone: (417) 625-5300
Billing
Attn: Lisha Hardy
Joplin R-VIII School District
1301 S Picher Ave, Joplin, MO 64804
Phone: (417) 625-5300 Ext: 2101
Email: lishahardy@joplinschools.org
Joplin R-VIII School District
1301 S Picher Ave, Joplin, MO 64804
Phone: (417) 625-5300 Ext: 2101
Email: lishahardy@joplinschools.org
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | telephone will not call out | 5/12/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | No | No | Fire Ext missing | 12/1/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.17 - Drive machine brake | 2.24.8.3 | Yes | No | Repair/Replace Emergency brake release assembly, non-functioning | 12/7/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.8 - Car safeties and guiding members - including roped-hydraulic elevators installed under A17.1b-1989 and later editions | 8.11.2.1.5(j) | Yes | No | Full-Load 5yr Weight Test Required. Annual portion completed 12/7/21 | 1/13/2022 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Full-Load 5yr Weight Test Required. Annual portion completed 12/7/21 | 1/13/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | Compliant/Required Documentation & MCP shall be kept in equipment room(neat/organized) including Wiring Diagrams, Oil log &Fire service log, recorded monthly. (Provided by Elev Co.) | 12/1/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | Provide mcp in machine room | 12/1/2023 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Provide current state operating certificate in machine room | 10/16/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | Provide MCP in machine room | 10/16/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Repair the emergency phone as it will not dial out. | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.1 - Access to machine space | 2.7.3.4 | No | No | Provide a stop switch adjacent to the access panel door, to the hoistway, in the machine room | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.4 Access to Pit | No | No | Add hand rail rungs at 12 inches on center from the floor level up to 42 inches above the floor as the left side handrail is not usable , it is to close to the door jamb. | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.3 - Lighting and receptacles | 2.7.5.1 | No | No | Provide at least 19 ftc at the floor level in front of the controller. | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Obtain and display a current state operating certificate in the machine room. |