Inspection
Inspection Details
Equipment ID
18937
18937
Inspection Date
10/26/2023
10/26/2023
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Jerry Eckhart
Jerry Eckhart
Mechanic Name
Walter Tauchert
Walter Tauchert
Relief Valve Pressure
640
640
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
19
19
External ID
bf0643ba-740c-4f05-b371-b5acf6770d3c
bf0643ba-740c-4f05-b371-b5acf6770d3c
Location
Beaumont Scout Reservation
6480 Beaumont Reservation Dr, High Ridge, MO
Phone: (636) 671-2481
6480 Beaumont Reservation Dr, High Ridge, MO
Phone: (636) 671-2481
Owner
Attn: Anthony Fouts
Boy Scouts of America- St. Louis
4568 W Pine Blvd, St. Louis, MO 63108
Phone: (314) 256-3130
Email: Anthony.fouts@scouting.org
Boy Scouts of America- St. Louis
4568 W Pine Blvd, St. Louis, MO 63108
Phone: (314) 256-3130
Email: Anthony.fouts@scouting.org
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | Yes | No | test and seal ruputure valve | 8/28/2018 |
| conversion | conversion | conversion - reinspect | Yes | No | cover hole in hositway above lower landing to maintain a on hour fire ratin | 8/28/2018 |
| conversion | conversion | conversion - reinspect | Yes | No | provide two way comunication in car, hands free phone | 8/28/2018 |
| conversion | conversion | conversion - reinspect | Yes | No | Install low pressure switch on hydraulic system high pressure side | 8/28/2018 |
| conversion | conversion | conversion - reinspect | Yes | No | Add latching circuitry to elevator controller for fire recall | 8/28/2018 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Provide two-way, hands free, communication inside car. | 7/3/2019 |
| A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 1002.2f | Yes | Yes | Add latching circuitry to elevator controller for fire recall. Did not red tag unit. Reinspect only. | 7/3/2019 |
| A17.1-1996 : Elevators | 2.5 - Housekeeping | 1206.2b (Clean Machine Room) | No | No | Machine space should not be used for storage. | 11/17/2021 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Expired | 11/12/2025 |
| A17.1-1996 : Elevators | 5.11 Plunger and Cylinder | 1206.5b(4) | No | No | No pit bucket. | 12/15/2022 |
| A17.1-1996 : Elevators | 5.11 Plunger and Cylinder | 1206.5b(4) | No | No | Terminate/remove scavenger lines returning to the tank. | 12/15/2022 |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 1206.2a (Pits and Hoistways) | No | No | Observed sump pump not plugged in. Determine if unit works, replace if needed. | 11/12/2025 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current certificate. | 11/12/2025 |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 1206.2a (Pits and Hoistways) | No | No | Observed sump pump not plugged in, in pit. SECOND NOTICE | 11/12/2025 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)10 Car Floors | No | No | Cab floor has broken floor tiles, a tripping hazard. Repair as needed. | 11/12/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Repair inoperative emergency phone | 11/12/2025 |
| MO Minimum : Elevators | (S) - Fire Service | 211.3a(8) Visual and audible signal | No | No | Repair inoperative in car phase I visual indicator. | 11/12/2025 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing (Re-Inspect) | Yes | No | OSV is not sealed and is due for full load test and tripping speed checked. Re-inspection required | |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 1206.2a (Pits and Hoistways) | No | No | Observed sump pump not plugged in. Determine if unit works, replace if needed. | |
| MO Minimum : Elevators | (S) - Fire Service | 211.3a(8) Visual and audible signal | No | No | Repair inoperative in car phase I visual indicator. |