Inspection
Inspection Details
Equipment ID
17921
17921
Inspection Date
9/7/2023
9/7/2023
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Daniel Letcher
Daniel Letcher
Mechanic Name
Jerry Reasoner
Jerry Reasoner
Relief Valve Pressure
n/a
n/a
Slide
n/a
n/a
Governor Rope Pull
n/a
n/a
Door Closing Force
19F/17R
19F/17R
External ID
85caba33-e707-4fe7-9704-f3df2366760b
85caba33-e707-4fe7-9704-f3df2366760b
Location
Argosy Casino Hotel
777 NW Argosy Pkwy, Riverside, MO
Phone: (816) 746-3100
777 NW Argosy Pkwy, Riverside, MO
Phone: (816) 746-3100
Owner
Attn: Argosy Casino
Argosy Casino
777 NW Argosy Pkwy, Riverside, MO 64150
Phone: (816) 746-3100
Email: susan.kuhn@pngaming.com
Argosy Casino
777 NW Argosy Pkwy, Riverside, MO 64150
Phone: (816) 746-3100
Email: susan.kuhn@pngaming.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | top of hoistway sprinkler line is not hooked up to the sprinkler system, it has been disconnected but the line into the hoistway is still there | 7/27/2018 |
| conversion | conversion | conversion - reinspect | Yes | No | coated steel belt monitor is flashing error that says it is time to replace the belts | 7/27/2018 |
| A17.1-1996 : Elevators | 3.26 - Broken rope, chain, or tape switch | 210.2(f) | Yes | No | belt monitor is flashing error on belt 3, hoist belts are roughed, belt monitor has been bypassed alowing the elevator to run. repair the belt monitor and clean the rouge off of the belts | 10/19/2020 |
| A17.1-2016 : Elevators | 3.23 - Suspension Means | 8.11.2.1.3(cc) | No | No | belt monitor is flashing an error on the center belt, if the belt tests good repair the belt monitor, otherwise replace the belts | 2/24/2023 |
| A17.1-2016 : Elevators | 3.11 - Hoistway smoke control | 8.11.2.1.3(q) | No | No | the smoke damper at the top of the hoistway is open, which means the damper motor has failed or that the damper motor has lost power. | 11/23/2025 |
| A17.1-2016 : Elevators | 3.12 - Pipes, wiring, and ducts | 8.11.2.1.3(r) | No | No | the sprinkler head at the top of the hoistway is not connected to a water supply line, it is just a pipe that goes through the wall | 11/23/2025 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.1(c) | No | No | post monthly fire service test log in the machine room | 11/23/2025 |
| A17.1-2016 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | a new copy of the state operating certificate is to be posted in the machine room every year | 11/23/2025 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | the state operating certificate posted in the machine room expired in 2011, update with a new copy when received from the state annually | 11/23/2025 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.4.1(c)(2) | No | No | monthly fire service test log has not been filled out monthly, test fire service monthly and fill out the log in the machine room | 11/23/2025 |
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | machine room maintenance logs have not been filled out since 2017, fill out log for every visit, callback, and maintenance | 11/23/2025 |
| A17.1-1996 : Elevators | 3.12 - Pipes, wiring, and ducts | 102 | No | No | the sprinkler line Projecting 3 feet into the hoistway is not hooked up to the building water supply, either apply for a variance to remove or repair and hook back up to the water supply | 11/23/2025 |
| A17.1-1996 : Elevators | 3.11 - Hoistway smoke control | 100.4 | No | No | the smoke damper at the top of the hoistway is fully open, which means the damper motor has failed or the the damper motor has lost power, repair smoke damper | 11/23/2025 |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | No | No | pit light is burnt out, replace light bulb | 11/23/2025 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | the state operating certificate posted in the machine room expired in 2011, update with current copy when received from the state of Missouri | |
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | monthly fire service test log has not been filled out | |
| A17.1-1996 : Elevators | 3.11 - Hoistway smoke control | 100.4 | No | No | the smoke damper at the top of the hoistway is open, which means the damper motor has failed or the the damper motor has lost power, should only open to prevent the accumulation of smoke and hot gases | |
| A17.1-1996 : Elevators | 3.12 - Pipes, wiring, and ducts | 102 | No | No | top of hoistway sprinkler line is not hooked up to the sprinkler supply line, it has been disconnected outside of the hoistway, elevator is equipped with belts that are not fire rated | |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1 | No | No | pit light is burnt out, replace pit light bulb | |
| A17.1-1996 : Elevators | 3.12 - Pipes, wiring, and ducts | 102 | No | No | 4x4 junction box behind the governor on the hoistway wall is missing it's cover | |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | The state operating certificate posted in the machine room expired in 2011, update with a new copy when received from the state annually | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.11.1 Firefighters' Emergency Operation & Documentation | No | No | Monthly fire service test log has not been filled out monthly, test fire service monthly and fill out log in the machine room | |
| A17.1-1996 : Elevators | 3.11 - Hoistway smoke control | 100.4 | No | No | the smoke damper at the top of the hoistway is open, which means the damper motor has failed or that the damper motor has lost power. | |
| A17.1-1996 : Elevators | 3.12 - Pipes, wiring, and ducts | 102 | No | No | top of hoistway sprinkler line is not hooked up to the sprinkler system, it has been disconnected but the line into the hoistway is still there. The coated steel belts are not Fire rated | |
| A17.1-1996 : Elevators | 3.12 - Pipes, wiring, and ducts | 102 | No | No | 4x4 junction box behind the governor at the top of the hoistway is missing it’s cover | |
| A17.1-1996 : Elevators | 3.2 - Car top light and outlet | 204.7 | No | No | car top light burnt out, replace bulb | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | The state operating certificate posted in the machine room expired in 2011, update with a new copy when received from the state annually. Repeat 9/2/2025 | |
| A17.1-1996 : Elevators | 3.11 - Hoistway smoke control | 100.4 | No | No | the smoke damper at the top of the hoistway is open, which means the damper motor has failed or that the damper motor has lost power. Repeat 9/2/2025 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | top of hoistway sprinkler line is not hooked up to the sprinkler system, it has been disconnected but the line into the hoistway is still there. Repeat 9/2/2025 The coated steel belts are not Fire rated | |
| A17.1-1996 : Elevators | 3.9 - Floor and emergency identification numbering | 100.7 | No | No | Floor 9 hoistway door needs to be numbered on the hoistway side | |
| A17.1-1996 : Elevators | 3.12 - Pipes, wiring, and ducts | 102 | No | No | 4x4 junction box behind the governor at the top of the hoistway is missing it’s cover. Repeat 9/2/2025 | |
| A17.1-1996 : Elevators | 3.2 - Car top light and outlet | 204.7 | No | No | car top light burnt out, replace bulb. Repeat 9/2/2025 |