Inspection
Inspection Details
Equipment ID
14494
14494
Inspection Date
10/25/2018
10/25/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Wayne Ingram
Wayne Ingram
Mechanic Name
Jamon Gray
Jamon Gray
Relief Valve Pressure
340
340
Slide
Governor Rope Pull
Door Closing Force
18
18
External ID
53ab06a9-a684-4f38-ad3f-acfc7540cde5
53ab06a9-a684-4f38-ad3f-acfc7540cde5
Location
Jordan Valley Parking Garage
815 E SAINT LOUIS ST, SPRINGFIELD, MO
815 E SAINT LOUIS ST, SPRINGFIELD, MO
Owner
Plaza Realty & Management Services LLC
815 E SAINT LOUIS ST, SPRINGFIELD, MO 65806-2417
815 E SAINT LOUIS ST, SPRINGFIELD, MO 65806-2417
Billing
Attn: Plaza Realty & Management Services LLC
815 E SAINT LOUIS ST, SPRINGFIELD, MO 65806-2417
815 E SAINT LOUIS ST, SPRINGFIELD, MO 65806-2417
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7 | No | No | Emergency Light Failed | 3/16/2021 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Obtain and display a current state operating certificate in the machine room | 4/7/2021 |
| A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1001.2(b)(7) | No | No | Have the fire extinguisher re-certified or replace it . Yours expired back in 2004 | 4/7/2021 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Obtain and display a current state operating certificate in the machine room | 4/22/2022 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Replace the bad mic to the phone | 1/4/2023 |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1 | No | No | Replace the burnt out pit light. | 4/22/2022 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.1(a) | No | No | lProvide a MCP in the machine room | 4/22/2022 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Phone not working properly. | 5/14/2024 |
| A17.1-2016 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | No | No | Out of date | |
| A17.1-2016 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post updated certificate. | |
| A17.1-2016 : Elevators | 5.15 - Overspeed Valve | 8.6.5.16.5 | No | No | 5 year test due on osv on or before next inspection | |
| A17.1-1996 : Elevators | 1.15 - sign and operating device symbols | 1001.2(a)(15) | No | No | phase 1 fire service key switch instructions not legible | |
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7 | No | No | missing drop ceiling to protect light bulb must replace or put protective tub over bulbs |