Inspection
Inspection Details
Equipment ID
19567
19567
Inspection Date
10/23/2023
10/23/2023
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Michael Bailey
Michael Bailey
Mechanic Name
Thomas Jimas
Thomas Jimas
Relief Valve Pressure
590
590
Slide
Na
Na
Governor Rope Pull
Na
Na
Door Closing Force
18 / 25
18 / 25
External ID
b65523f1-0de7-4660-9fac-fbea0fa48685
b65523f1-0de7-4660-9fac-fbea0fa48685
Location
Air Products Prism Membranes
11444 Lackland Rd, St. Louis, MO
Phone: (314) 392-3600
11444 Lackland Rd, St. Louis, MO
Phone: (314) 392-3600
Owner
Attn: Larry
Air Products Prism Membranes
11444 Lackland Rd, St. Louis, MO 63146
Phone: (314) 392-3600
Email: LAUCKL@airproducts.com
Air Products Prism Membranes
11444 Lackland Rd, St. Louis, MO 63146
Phone: (314) 392-3600
Email: LAUCKL@airproducts.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Clean oil from elevator pit. | 7/23/2018 |
| conversion | conversion | n/a | No | No | Repair cab emergency lights | 7/23/2018 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.16 - Rated load, platform area, and data plate | 8.11.2.1.1(p) | No | No | There car capacity plate inside the elevator stating the rated load of the car is unreadable and shall be replaced. | 10/7/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.1 - Access to machine space | 8.11.2.1.2(a) | No | No | The elevator machine room door shall be repaired to be self-closing and self-locking and shall be operable from the interior space without the use of a key. | 10/7/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | The fireman's emergency service instructions are unreadable inside the car and shall be replaced. | 10/7/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | The rear car door direction arrow has been damaged and shall be replaced to operate as required | 10/7/2025 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | The current state operating certificate needs to be posted in the machine room in a non-combustible frame. | 10/7/2025 |
| A17.1-2016 : Elevators | 5.15.2 Unsealed Overspeed Valve | 8.6.5.16.5 (Re-Inspect) | Yes | No | OSV is not sealed and needs full load test and tripping speed checked. Re-inspection required | 12/20/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Need to replace direction arrow in cab, front & back | 10/7/2025 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | 2 way communication is not working when the power is off. Re-inspection required | 10/23/2023 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | Yes | No | Auxiliary lighting inoperable, repair or replace. | 2/21/2025 |