Inspection
Inspection Details
Equipment ID
14386
14386
Inspection Date
10/26/2023
10/26/2023
Inspection Type
Major Alteration
Major Alteration
Inspector Name
Christopher "RED" Staton
Christopher "RED" Staton
Mechanic Name
Vincent Langendoerfer
Vincent Langendoerfer
Relief Valve Pressure
NA
NA
Slide
TBD
TBD
Governor Rope Pull
50/625
50/625
Door Closing Force
TBD
TBD
External ID
d224464f-9fd1-4e1b-935d-c9f9e9792b93
d224464f-9fd1-4e1b-935d-c9f9e9792b93
Location
Senate Apartments
265 Union Blvd, St. Louis, MO
Phone: (314) 367-7900
265 Union Blvd, St. Louis, MO
Phone: (314) 367-7900
Owner
Attn: Accounts Payable
275 on the Park
11766 Wilshire Blvd, Ste 325, Los Angeles, CA 90025
Phone: (281) 888-0832
275 on the Park
11766 Wilshire Blvd, Ste 325, Los Angeles, CA 90025
Phone: (281) 888-0832
Billing
Attn: Accounts Payable
275 on the Park - Annex
10330-DD Lake Rd, Houston, TX 77070
Phone: (281) 888-0832
Email: AP@unified-residential.com
275 on the Park - Annex
10330-DD Lake Rd, Houston, TX 77070
Phone: (281) 888-0832
Email: AP@unified-residential.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | x | In cab emergency telephone shall work. | 10/18/2018 | |
| conversion | conversion | conversion - reinspect | x | Car top emergency exit must be secured to car top and shall only be able to open from the car top without the use of tools. | 10/18/2018 | |
| conversion | conversion | conversion - reinspect | x | Car door restrictor shall work. | 10/18/2018 | |
| A17.1-1996 : Elevators | 3.8 - Top emergency exit | 1001.2(c)(12) | Car top exit shall be properly secured. | |||
| A17.1-1996 : Elevators | 2.1 - Access to machine space | 1001.2(b)(1) | Provide code compliant machine room door handle and lock. | |||
| A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1001.2(b)(7) | An ABC type fire extinguisher shall be kept in the machine room. | |||
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Display the current state operating certificate. | |||
| A17.1-1996 : Elevators | 2.8 - Pipes, wiring, and ducts | 1001.2(b)(8) | All pipes conveying liquid, vapor, or gas that are above or come near elevator equipment shall be guarded or guttered. | |||
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | The pit lighting shall be operational. | |||
| A17.1-1996 : Elevators | 5.9 - Buffers and emergency terminal speed limiting devices | 1002.3f | x | The elevator makes contact with the with the car buffer every time the car reaches the bottom landing. Take corrective action. | 7/5/2022 | |
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | |||
| A17.1-1996 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 111.5 Restricted Opening of Hall/Car Doors | x | The car door restrictor shall be operational. | 7/5/2022 | |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | The in car emergency telephone shall be operational. | 7/5/2022 | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | The category 5 test is incomplete. The following testing item remains: The safeties shall be set with a full load and a slide measurement shall be provided. | 7/5/2022 | |
| A17.1-1996 : Elevators | 5.9 - Buffers and emergency terminal speed limiting devices | 1002.3f | x | The elevator makes contact with the with the car buffer every time the car reaches the bottom landing. Take corrective action. (Prior inspection violation that has yet to be cleared). | 10/26/2023 | |
| A17.1-1996 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 111.5 Restricted Opening of Hall/Car Doors | x | The car door restrictor shall be operational. (Prior inspection violation that has yet to be cleared). | 10/26/2023 | |
| A17.1-1996 : Elevators | 2.8 - Pipes, wiring, and ducts | 102.2 | Condensation is dripping on duct. All pipes conveying liquid, vapor, or gas that are above or come near elevator equipment shall be guarded or guttered. | |||
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | Could not test wind-up safeties. A tool to reset the car safeties shall be available on-site and the safeties shall be tested. | 10/26/2023 | |
| A17.1-1996 : Elevators | 2.11 - Disconnecting Means and Control | 210.4 | 110V disconnect shall be labeled. Where there is more than one machine in a room, the disconnect for each machine shall be conspicuously numbered to correspond to the machine it controls. | |||
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | Category 5 test is still incomplete. All parts of the category 5 test remain except the governor pullout/pullthru and governor switch/jaw. | 10/26/2023 | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | Inspection is still incomplete. Still need to check pit, restrictor, and SOS. | 10/26/2023 | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | Acceptance test incomplete. Remaining items: measure slide, 100% car buffer, 0% CW buffer, emergency light/alarm/phone, door pressure, phase 1 & 2 fire service, in-car stop, communication loss, runby measurement, traction loss detection. | 11/2/2023 | |
| A17.1-2016 : Elevators | 2.3 - Lighting and receptacles | 2.7.9.1 | x | Check machine room for adequate lighting (not less than 19 fc at floor). | 11/2/2023 | |
| A17.1-2016 : Elevators | 2.8 - Pipes, wiring, and ducts | 2.8.2 | x | Machine room heat detectors failed to initiate recall or shunt (4 devices). | 11/2/2023 | |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Two-way communication device shall work. The button lights up, but does not dial (communication loss works). | ||
| A17.1-2016 : Elevators | 2.17 - Drive machine brake | 2.24.8.3 | x | 2.24.8.4 - Emergency brake release module shall work and be retested. | ||
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | |||
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1 | Pit shall be kept clean. Remove excess debris. |