Inspection
Inspection Details
Equipment ID
22771
22771
Inspection Date
11/3/2023
11/3/2023
Inspection Type
Reinspection
Reinspection
Inspector Name
Michael Ledden
Michael Ledden
Mechanic Name
Carl Tiemann
Carl Tiemann
Relief Valve Pressure
1000
1000
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
21F/23R
21F/23R
External ID
7fa7f198-a42e-4945-865f-b8854242ec1f
7fa7f198-a42e-4945-865f-b8854242ec1f
Location
MO Baptist University - Spartan Field
1 College Park Dr, Creve Coeur, MO
Phone: (314) 434-1115
1 College Park Dr, Creve Coeur, MO
Phone: (314) 434-1115
Owner
Attn: MO Baptist University
MO Baptist University
1 College Park Dr, St. Louis, MO 63141
Phone: (314) 744-7623
Email: john.shaw@mobap.edu
MO Baptist University
1 College Park Dr, St. Louis, MO 63141
Phone: (314) 744-7623
Email: john.shaw@mobap.edu
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.31 - Slack Rope Device - Roped-Hydraulic Elevators Installed Under A17.1b-1989 and Later Editions | 8.11.3.1.3(z) | No | Yes | Slack cable switch not operating. Unit Red-Tagged. | 2/15/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | Provide code compliant maintenance records. | 12/24/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Display a copy of the current state operating certificate in the machine room. | 12/17/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 10/15/2020 |
| A17.1-2016 : Elevators | 5.11 - Plunger and Cylinder | 8.6.5.5 | No | No | 8.6.5.5.2 - Oil leakage collected from each cylinder head seal or packing gland shall not exceed 5 gallons before removal. (The oil recovery line from the hydraulic head is presently being run directly to the tank - oil loss cannot be monitored) | 10/15/2020 |
| A17.1-2016 : Elevators | 2.13 - Governor, Overspeed Switch, and Seal | 8.11.3.1.2(bb) | No | No | The governor shall have a test tag installed. | 6/29/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.8 - Car safeties and guiding members - including roped-hydraulic elevators installed under A17.1b-1989 and later editions | 8.11.3.1.5 (j) Car Safety | No | No | A category 5 test shall be performed. | 6/29/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.34 - Flexible Hydraulic Hose and Fitting Assemblies | 3.19.3.3 Flexible Hydraulic Connections | Yes | Yes | A hydraulic hose in the pump unit ruptured. Elevator Red Tagged. | 11/3/2023 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | All annual inspection items still need to be witnessed with the exception of the hoistway scan. | 11/3/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 3.27 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone shall be operational. | 9/26/2025 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing | No | No | A category 5 test shall be performed on the overspeed valve in 2025. Note: Unit is a LU/LA and may have other items that need category 5 testing. | 9/26/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 3.27 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | Yes | Emergency communications/phone still not working. Elevator Red Tagged out of service. | 10/16/2025 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing (Re-Inspect) | Yes | No | A category 5 test shall be performed on the overspeed valve in 2025. Note: Unit is a LU/LA and may have other items that need category 5 testing. | 10/16/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | The phone shall establish two-way communication and give location of the elevator on battery back up. |