Inspection
Inspection Details
Equipment ID
7058
7058
Inspection Date
11/20/2023
11/20/2023
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Mitchell McNeely
Mitchell McNeely
Mechanic Name
Jeffrey Miller
Jeffrey Miller
Relief Valve Pressure
470
470
Slide
Governor Rope Pull
Door Closing Force
18/20
18/20
External ID
ed2850a6-4a54-4cba-94bf-d315d3e210ea
ed2850a6-4a54-4cba-94bf-d315d3e210ea
Location
Grand Center
3526 Washington Ave, St. Louis, MO
Phone: (314) 289-1512
3526 Washington Ave, St. Louis, MO
Phone: (314) 289-1512
Owner
Attn: Kim Stelzer
3526 Washington Avenue Condominium Association
3526 Washington Ave, St. Louis, MO 63103
Phone: (314) 289-1512
Email: Kim@grandcenter.org
3526 Washington Avenue Condominium Association
3526 Washington Ave, St. Louis, MO 63103
Phone: (314) 289-1512
Email: Kim@grandcenter.org
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | Car lights need to be repaired. | 2/23/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone does not work on 110v or normal power | 11/22/2021 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current state operating certificate shall be displayed in the machine room | 6/27/2023 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone is not working. Re-inspection required | 2/28/2023 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current operating certificate shall be displayed in the machine room | 6/27/2023 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone is not working. Re-inspection required | 4/19/2023 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone in car is not working on 110V or normal power. Re-inspection required | 4/19/2023 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Remove all non-elevator materials from the machine room entrance. | 1/27/2025 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 1/27/2025 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | 2-way communication device shall work. | |
| A17.1-2016 : Elevators | 4.2 - Hoistway doors | 8.6.4.13 Door Systems | No | No | Hoistway door lower stafty retainers/fire tabs shall be installed at bottom of hoistway doors. (2nd floor door missing tab, all other floors are compliant.) | |
| A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 8.6.11.1 Firefighters’ Emergency Operation Documentation | No | No | Fire service testing shall be documented monthly. | |
| A17.1-2016 : Elevators | 1.5 - Car lighting and receptacles | 8.10.2.2.1(e) | No | No | There is no cab lighting disconnecting device in the machine room nor documentation as to where the location of the circuit breaker. Either install disconnecting device or provide location of breaker for future testing/work. |