Inspection
Inspection Details
Equipment ID
12869
12869
Inspection Date
11/12/2023
11/12/2023
Inspection Type
Alteration
Alteration
Inspector Name
Michael Gallaher
Michael Gallaher
Mechanic Name
Matthew Toettcher
Matthew Toettcher
Relief Valve Pressure
Na
Na
Slide
Na
Na
Governor Rope Pull
Na
Na
Door Closing Force
Na
Na
External ID
ff8af6fe-0045-49dc-8d20-d3cb3974fb3f
ff8af6fe-0045-49dc-8d20-d3cb3974fb3f
Location
The Lofts at 1 Thousand
1000 Washington Ave, St. Louis, MO
Phone: (314) 436-6800
Alt Phone: (314) 435-9338
Email: cratermann@mandelgroup.com
1000 Washington Ave, St. Louis, MO
Phone: (314) 436-6800
Alt Phone: (314) 435-9338
Email: cratermann@mandelgroup.com
Owner
Attn: Clay Ratermann
Mandel Group
1000 Washington Ave, St. Louis, MO 63101
Phone: (314) 436-6800
Alt Phone: (314) 435-9339
Fax: (314) 436-8532
Email: kbanks@mandelgroup.com
Mandel Group
1000 Washington Ave, St. Louis, MO 63101
Phone: (314) 436-6800
Alt Phone: (314) 435-9339
Fax: (314) 436-8532
Email: kbanks@mandelgroup.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 2.5 - Housekeeping | 1001.2(b)(5) | No | No | The elevator machine room cannot be used for storage. Remove the items being stored in the machine room to provide proper room for maintenance to be performed. | 11/7/2023 |
| A17.1-1996 : Elevators | 3.28 - Counterweight and counterweight buffer | 1001.2(c)(13) | Yes | No | There is a top and bottom guide roller on the counterweight that has deteriorated and shall be replaced. | 7/29/2022 |
| A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 1002.2f | Yes | No | The fireman's emergency service phase I and II operations was tested and the following deficiency was noted: - The fireman service phase I key switch housing is damaged and shall be replaced. Reinspection required. | 7/29/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | The signage for “In Case of Fire” is missing on a number of landings. Install signage that conforms to the building code this elevator was installed to meet. | 11/7/2023 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Remove non elevator related materials from machine room | 11/7/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Elevator pit shall be cleaned | 11/7/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Replace worn guide rollers / shoes on the top of counterweight | 11/7/2023 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency communication inoperable. Re-inspection required | 8/21/2023 |
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) | Yes | No | Emergency light in the cab does not work on emergency 110v power | 11/12/2023 |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | Yes | Yes | One of the suspension ropes has frayed/broke. Ropes shall be replaced and reinspected | 11/12/2023 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State Elevator Certificate. | |
| A17.1-1996 : Elevators | 1.17 - Standby power operation | 1002.2g (Standby Power Operation) | Yes | No | Provide testing of the elevator on emergency power. | |
| A17.1-1996 : Elevators | 4.12 - Standby power selection switch | 1002.2g | Yes | No | Provide testing of the elevator emergency power selector switch, located in the Fire Command Room. | |
| A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1206.1h | No | No | Provide current year tested fire extinguisher in the elevator machine room. | |
| A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 211.7 Firefighter' Service Operating Procedures | No | No | Post Phase I instructions near the f/f switch in the lobby. |