Inspection
Inspection Details
Equipment ID
2346
2346
Inspection Date
11/28/2023
11/28/2023
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
James VanZant
James VanZant
Mechanic Name
Shaun Deckard
Shaun Deckard
Relief Valve Pressure
390
390
Slide
Governor Rope Pull
Door Closing Force
26
26
External ID
c4fd2040-1d2f-43f0-b087-61558a760cbb
c4fd2040-1d2f-43f0-b087-61558a760cbb
Location
Tyson Foods- Noel
1 Tyson Ave, Noel, MO
Phone: (417) 475-8265
1 Tyson Ave, Noel, MO
Phone: (417) 475-8265
Owner
Attn: Tyson Foods- Noel
Tyson Foods- Noel
1 Tyson Ave, Noel, MO 64854
Phone: (417) 475-3181
Email: ryan.schenkel@tyson.com
Tyson Foods- Noel
1 Tyson Ave, Noel, MO 64854
Phone: (417) 475-3181
Email: ryan.schenkel@tyson.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | G(1)/8.6.4.15/1.5.1(b) : Emergency/auxiliary lighting shall work with power loss. (REINSPECTION REQUIRED) | 1/19/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | G/2.7.1/8.6.1.6.5: Machine Room Fire Extinguisher shall have current monthly/annual test tag. (Expired) | 1/21/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | No | No | MCP shall be kept in equipment room, including Oil loss log and Fire service testing log, recorded monthly. | 1/21/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Repair rear handrail inside cab | 1/21/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.2 Oil Leakage Collection | No | No | G/8.6.5.5.2 Pit scavenger pump will be removed or routed to a measurable container. | 1/21/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.7 Cleaning of Hoistway and Pit | No | No | clean cartop and pit, excessive debris | 1/21/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | G(1)/8.6.4.15/1.5.1(b) : Emergency/auxiliary lighting shall work with power loss. (REINSPECTION REQUIRED) | 1/19/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | Replace missing hall fire signage “ in case of fire…..” | 3/15/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | G(1)/A17.1-2016:8.6.1.6 :Compliant/Required Documentation & MCP shall be kept in equipment room(neat/organized) | 3/15/2022 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Machine room door shall be self-closing and self-locking. Push button locking not allowed, and closer does not fully close door. | 3/15/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | 11 CSR 40-5.070 : ADA Requirements: buttons missing Braille Identification. | 3/15/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Repair COP side reveal panel (damaged, exposing bulbs and wiring) | 3/15/2022 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | H(5) Machine room lighting needs to be guarded | 3/15/2022 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Machine room light must be guarded | 6/22/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.1 General Maintenance Requirements Documentation | No | No | Provide mcp in machine room | 6/22/2023 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Machine lighting must be protected | 12/4/2023 |