Inspection
Inspection Details
Equipment ID
21271
21271
Inspection Date
11/28/2023
11/28/2023
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Thomas McGrath
Thomas McGrath
Mechanic Name
Richard King
Richard King
Relief Valve Pressure
NA
NA
Slide
NA
NA
Governor Rope Pull
NA/NA
NA/NA
Door Closing Force
NA
NA
External ID
681f71c6-0e0b-4695-9c07-b8f7af54be4d
681f71c6-0e0b-4695-9c07-b8f7af54be4d
Location
Michaels
1516 S Brentwood Blvd, Brentwood, MO
Phone: (314) 918-8189
1516 S Brentwood Blvd, Brentwood, MO
Phone: (314) 918-8189
Owner
Attn: MICHAEL'S c/o Pace Properties
Pace Properties- Brentwood
1401 S Brentwood Blvd, Brentwood, MO 63144
Phone: (469) 759-5366
Alt Phone: (469) 621-0908
Email: DMF.Escalation@michaels.com
Pace Properties- Brentwood
1401 S Brentwood Blvd, Brentwood, MO 63144
Phone: (469) 759-5366
Alt Phone: (469) 621-0908
Email: DMF.Escalation@michaels.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | Yes | No | Replace broken combination teeth top and bottom | 2/9/2022 |
| conversion | conversion | conversion - reinspect | Yes | No | Demarcation lights out top and bottom | 2/9/2022 |
| Missouri Minimum : Escalators | CSR 40-5.100 State Operating Certificate | 5.100(2) display of certificate | No | No | Post current certificate. | 10/16/2025 |
| Missouri Minimum : Escalators | CSR 40-5.100 State Operating Certificate | 5.100(2) display of certificate | No | No | Post current state certificate in machine room | 10/16/2025 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.11.5.2(i) Demarcation lighting | Yes | No | Repair top demarcation light | 10/8/2024 |
| Missouri Minimum : Escalators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Complete annual testing within 30 days, test brake torque | 10/8/2024 |
| A17.1-2016 : Elevators | 7.5 - Lighting | 6.1.7.1.1 | Yes | No | Top and bottom Demarcation lighting shall be wired to meet NFPA 70 | 8/7/2025 |
| A17.1-2016 : Elevators | 7.10 - Operating and safety devices | 6.1.6 | No | No | Repair upper and lower stop switch cover for proper operation. Alarm not sounding when lid is lifted | 10/16/2025 |
| A17.1-1996 : Escalators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Certificate | No | No | Post current State Elevator Certificate. | 10/16/2025 |
| Missouri Minimum : Escalators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Provide brake torque test, record results. | 10/16/2025 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Indexing test failed, repair as needed. | 10/16/2025 |
| A17.1-1996 : Escalators | 7.17 - Step/skirt clearances, panels, and performance index | 802.3e | Yes | No | Step indexing measurements were above allowable tolerances, need repaired. Re-inspection required |