Inspection
Inspection Details
Equipment ID
8743
8743
Inspection Date
10/18/2023
10/18/2023
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
David Folkert
David Folkert
Mechanic Name
Dennis Smith
Dennis Smith
Relief Valve Pressure
na
na
Slide
na
na
Governor Rope Pull
na
na
Door Closing Force
25
25
External ID
c69cd666-2f29-4978-bd3f-88990cd68471
c69cd666-2f29-4978-bd3f-88990cd68471
Location
Village East Towers LTD
1218 VILLAGE DR, SAINT JOSEPH, MO
Phone: (816) 364-5593
1218 VILLAGE DR, SAINT JOSEPH, MO
Phone: (816) 364-5593
Owner
Attn: Maintenance Supervisor
Village East Towers LTD
1218 Village Dr, St. Joseph, MO 64506
Phone: (816) 364-5593
Fax: (816) 232-5323
Email: Kevin.gray@conam.us
Village East Towers LTD
1218 Village Dr, St. Joseph, MO 64506
Phone: (816) 364-5593
Fax: (816) 232-5323
Email: Kevin.gray@conam.us
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.12 - Pipes, wiring, and ducts | 8.11.2.1.3(r) | No | No | Install covers on 4x4 electrical gangboxes at top of hoistway | 2/22/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.27 - Crosshead data plate | 8.11.2.1.3(k) | No | No | Install suspension rope data tag to ropes | 2/22/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 2.12.5 Restricted Opening of Hoistway or Car Doors (Re-Inspection) | Yes | No | Car door restrictor does not function. | 11/19/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.12 - Pipes, wiring, and ducts | 8.11.2.1.3(r) | No | No | Install covers on conduit pullboxes located near top of hoistway. | 11/19/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.11.1 | No | No | Test and log firefighter operation monthly | 11/19/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.9 - Guarding of exposed auxiliary equipment | 2.10.1 | No | No | Provide guarding of machine drive sheave and hoist ropes. | 11/19/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.16 - Rated load, platform area, and data plate | 2.16.3.1 Capacity Plates | No | No | Install 2500 LBS Capacity plate inside the elevator. The existing capacity plate does not correspond with crosshead data plate. | 6/21/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.16 - Rated load, platform area, and data plate | 2.16.3.1 Capacity Plates | No | No | Install capacity plate inside the elevator "2000 lbs Capacity" | 11/13/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.1 - Access to machine space | 2.7.3.4 | No | No | Machine room access door shall be self-closing | 11/13/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 2.12.5 Restricted Opening of Hoistway or Car Doors (Re-Inspection) | Yes | No | Car door restrictor does not function | 5/16/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.7.2 Periodic Test Record (Test Tags) | No | No | Install and date period test tag | 11/13/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.8 - Door closing force | 2.13.4.2.3 | Yes | No | REDUCE DOOR TORQUE TO LESS THAN 30lbs | 10/10/2025 |