Inspection
Inspection Details
Equipment ID
14852
14852
Inspection Date
12/5/2023
12/5/2023
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Steven Salabay
Steven Salabay
Mechanic Name
Ken Koppel
Ken Koppel
Relief Valve Pressure
420
420
Slide
NA
NA
Governor Rope Pull
NA/Na
NA/Na
Door Closing Force
24/20
24/20
External ID
b02ac6dc-6d18-4f45-b6cd-2283ac94ae1f
b02ac6dc-6d18-4f45-b6cd-2283ac94ae1f
Location
Hampton Inn & Suites
5650 Oakland Ave, St. Louis, MO
Phone: (314) 655-3993
5650 Oakland Ave, St. Louis, MO
Phone: (314) 655-3993
Owner
Attn: Hampton Inn & Suites- Forest Park
Hampton Inn & Suites- Forest Park
5650 Oakland Ave, St. Louis, MO 63110
Phone: (314) 655-3993
Email: garrett@raymondteam.com
Hampton Inn & Suites- Forest Park
5650 Oakland Ave, St. Louis, MO 63110
Phone: (314) 655-3993
Email: garrett@raymondteam.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7 | No | No | Repair emergency light in car | 12/13/2018 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | provide monthly fire service test & document on log in machine room | 2/1/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | provide maintenance control program | 2/1/2022 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current state certificate in machine room | 2/1/2022 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform monthly fire service test & document on log in machine room | 2/1/2022 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Celan oil from the pit floor | 2/1/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.1 General Maintenance Requirements Documentation | No | No | Provide maintenance control program | 2/1/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.1 Examination and Maintenance | Yes | No | Repair/replace leaking overspeed valve & perform 5 year test;; Reinspection required | 12/5/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Clean oil from pit floor | 12/31/2022 |
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | A code compliant MCP and all the on-site documentation required shall be provided in the machine room. | 12/8/2025 |
| A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 1002.2f | Yes | No | On fire service, doors will not close. Take corrective action and re-test. | 8/18/2025 |
| A17.1-1996 : Elevators | 1.16 - Rated load, platform area, and data plate | 207 | No | No | Capacity tag shall be installed in car. | 12/8/2025 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Elevator dropped during 1st static test. Unit stayed level during 2nd static test but the valbe to the take was shut off. Repair valve as required. | 4/30/2026 |