Inspection
Inspection Details
Equipment ID
4084
4084
Inspection Date
11/22/2023
11/22/2023
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Robert Kehm
Robert Kehm
Mechanic Name
David Howerton
David Howerton
Relief Valve Pressure
480
480
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
NA
NA
External ID
0a83d0c2-2f92-4431-b5a5-de4043ce51b7
0a83d0c2-2f92-4431-b5a5-de4043ce51b7
Location
Refurbiture Inc.
5642 Natural Bridge Ave, St. Louis, MO
Phone: (314) 389-4140
5642 Natural Bridge Ave, St. Louis, MO
Phone: (314) 389-4140
Owner
Attn: Josh Richie
Refurbiture Inc.
5642 Natural Bridge Ave, St. Louis, MO 63120
Phone: (618) 409-0563
Email: jrichie@refurbitureinc.com
Refurbiture Inc.
5642 Natural Bridge Ave, St. Louis, MO 63120
Phone: (618) 409-0563
Email: jrichie@refurbitureinc.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.3 Guards Between Adjacent Pits | Remove the oil and water from the pit. | 9/18/2023 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.5 - Housekeeping | 8.11.2.1.2(e) (Re-Inspection) | Equipment and materials not related to the operation or maintenance of the elevator shall not be stored in the elevator machine room. | 4/26/2022 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.1 - Access to machine space | 8.11.2.1.2(a) | The entrance to the machine room shall be maintained in a clear and unobstructed manner. The boxes & pallets obstructing the machine room entry shall be removed. | 9/18/2023 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.11 Periodic Inspection and Test. | x | Could not perform the relief valve verification of setting and system pressure test. The relief pressure shall be tested and obtained. | 4/26/2022 | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | Written evacuation procedures for elevators by authorized persons and emergency personnel shall be available on-site. | 9/18/2023 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 9/18/2023 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.11 - Disconnecting Means and Control | 2.26.4 | The disconnect located in the machine room shall be provided with a sign to identify the location of the supply side overcurrent protective device. | 9/18/2023 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | Clean the pit of dirt, debris, and oil. | 9/18/2023 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.11 - Plunger and Cylinder | 8.6.5.8 Safety Bulkhead | x | Need to determine if this unit is a single bottom jack. Take corrective action if unit is confirmed to be a single bottom jack. If unit is determined to be double bottom type then documentation shall be kept on-site in the machine room. | 4/26/2022 | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.33 - Tanks | 8.11.3.1.2(p) | The hydraulic tank drip pan has an excessive amount of oil, it shall be cleaned. | 9/18/2023 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.1 - Access to machine space | 8.11.2.1.2(a) | The entrance to the machine room shall be maintained in a clear and unobstructed manner. The boxes and pallets obstructing the machine room entry shall be removed. | 9/18/2023 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.7 - Car door or gate | 8.11.2.1.1(g) | The car gate will not operate when the open or close button is activated. | 9/18/2023 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.16 - Rated load, platform area, and data plate | 8.11.2.1.1(p) | Install a loading class plate conspicuously on the elevator car. | 9/18/2023 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.3 - Lighting and receptacles | 8.11.3.1.2(c) | The lighting in the machine room shall not be less than 10 foot candles measured at the floor. Increase the lighting. | 9/18/2023 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.8 - Pipes, wiring, and ducts | 8.11.2.1.2(h) | Machine rooms that have pipes carrying liquids, gas, or vapors that cross overhead of the elevator equipment or come in close proximity of the equipment shall be guarded or guttered. | 9/18/2023 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.1 - Access to machine space | 8.11.2.1.2(a) | All room enclosures shall have a self-closing and self-locking door and shall be operable from the interior space without the use of a key. | 9/18/2023 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.5 - Housekeeping | 8.11.2.1.2(e) (Re-Inspection) | The machine room shall be cleaned of dirt and excessive amount of dust. | 4/26/2022 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current MO State operating certificate shall be obtained and displayed in the elevator machine room. | 9/18/2023 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. | 9/18/2023 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.7 - Car door or gate | 8.11.2.1.1(g) | The car gate will not operate when the open or close button is activated. | 9/18/2023 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.16 - Rated load, platform area, and data plate | 8.11.2.1.1(p) | Install a loading class plate conspicuously on the elevator car. | 9/18/2023 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.8 - Pipes, wiring, and ducts | 8.11.2.1.2(h) | Machine rooms that have pipes carrying liquids, gas, or vapors that cross overhead of the elevator equipment or come in close proximity of the equipment shall be guarded or guttered. | 9/18/2023 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.1 - Access to machine space | 8.11.2.1.2(a) | All room enclosures shall have a self-closing and self-locking door and shall be operable from the interior space without the use of a key. | 9/18/2023 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.11 - Disconnecting Means and Control | 2.26.4 | The disconnect located in the machine room shall be provided with a sign to identify the location of the supply side overcurrent protective device. | 9/18/2023 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 3/3/2025 |