Inspection
Inspection Details
Equipment ID
4536
4536
Inspection Date
9/28/2017
9/28/2017
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Gregory Sacks
Gregory Sacks
Mechanic Name
Relief Valve Pressure
340
340
Slide
Governor Rope Pull
Door Closing Force
20
20
External ID
Location
Carrington Place of St. Charles
2150 Randolph, St. Charles, MO
Phone: (636) 946-4966
2150 Randolph, St. Charles, MO
Phone: (636) 946-4966
Owner
Carrington Place of St. Charles
2150 Randolph, St. Charles, MO 63301
2150 Randolph, St. Charles, MO 63301
Billing
Attn: Carrington Place of St. Charles
2150 Randolph, , MO 63301
2150 Randolph, , MO 63301
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | The pit shall be clean of oil and debris. | 9/11/2018 |
| conversion | conversion | n/a | No | No | The car door roller(s) are bad. Door does not operate smoothly. | 9/11/2018 |
| conversion | conversion | n/a | No | No | The emergency light and alarm does not work. | 9/11/2018 |
| conversion | conversion | n/a | No | No | The emergency light and alarm does not work. | 9/11/2018 |
| conversion | conversion | n/a | No | No | The pit shall be clean of oil and debris. | 9/11/2018 |
| conversion | conversion | n/a | No | No | The car door roller(s) are bad. Door does not operate smoothly. | 9/11/2018 |
| A17.1-1996 : Elevators | 3.3 - Top-of-car operating device | 1001.2(c)(3) | No | No | Repair damaged car top run station. - Reinspection Required | 2/6/2024 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Display current state operating certificate. | 2/6/2024 |
| A17.1-2016 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | Oil shall not accumulate on the pit floor. The pit shall be cleaned. | 2/6/2024 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 9/28/2023 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | A17.1 2016 8.6.4.15 - The in car emergency telephone shall be operational. | 9/23/2022 |
| A17.1-1996 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 111.5 Restricted Opening of Hall/Car Doors | Yes | No | The means to restrict opening of the car door shall be operational. | 9/23/2022 |
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. | 2/6/2024 |
| A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 211.8 Switch Keys | Yes | No | Keys to test fire service are not on-site. Fire service shall be tested to complete the annual inspection. All elevators in the building shall be operable by the FEO-K1 key. These keys should be on premises in a location accessible to firefighters and emergency personnel, but not to the public. | 12/29/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | No | No | First floor hall light does not work. Control & operating devices and controls shall be maintained. | 2/6/2024 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | The emergency phone answers but hangs up. The in car emergency phone shall be operational and code compliant. | 12/29/2023 |
| A17.1-1996 : Elevators | 1.17 - Standby power operation | 211.2 | Yes | No | Elevators that are equipped to operate on emergency power shall be tested with no load in the car while operating on the emergency generator. | 12/29/2023 |