Inspection
Inspection Details
Equipment ID
11758
11758
Inspection Date
12/19/2023
12/19/2023
Inspection Type
Reinspection
Reinspection
Inspector Name
Steven Salabay
Steven Salabay
Mechanic Name
Relief Valve Pressure
NA
NA
Slide
NA
NA
Governor Rope Pull
NA/NA
NA/NA
Door Closing Force
NA
NA
External ID
0346c5a2-5a00-4002-94f7-7729a191d200
0346c5a2-5a00-4002-94f7-7729a191d200
Location
Homestead Studio Suites
11252 Lone Eagle Dr, Bridgeton, MO
Phone: (314) 739-0600
11252 Lone Eagle Dr, Bridgeton, MO
Phone: (314) 739-0600
Owner
Attn: ESA CERT MGMT
ESA Elevator Management c/o Lerch Bates
9780 S Meridian Blvd, Ste 450, Englewood, CO 80112
Phone: (303) 795-7956
Alt Phone: (303) 723-7929
Email: Extendedstay.elevators@lerchbates.com
ESA Elevator Management c/o Lerch Bates
9780 S Meridian Blvd, Ste 450, Englewood, CO 80112
Phone: (303) 795-7956
Alt Phone: (303) 723-7929
Email: Extendedstay.elevators@lerchbates.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Post current State certificate in machine room | 7/2/2019 |
| conversion | conversion | n/a | No | No | Repair light on top of the car | 7/2/2019 |
| conversion | conversion | n/a | No | No | Repair pit light | 7/2/2019 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State certificate in machine room | 8/20/2019 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State certificate in machine room | 6/17/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | Need maintenance control program on site posted on controller | 6/17/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Muffler on oil line leaking badly when testing | 6/17/2020 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current state certificate in machine room | 6/7/2021 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform monthly fire service testing and document on log in machine room | 6/7/2021 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Perform annual test within 30 days | 1/17/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Clean pit | 4/6/2023 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current state certificate in machine room | 4/6/2023 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform monthly fire service testing and document on log in machine room | 4/6/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Clean pit | 12/15/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | Yes | No | Pit needs cleaning | 1/9/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current state certificate in machine room | 7/30/2024 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform monthly fire service testing and document on log in machine room | 7/30/2024 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | Yes | No | Top of the jack drain line is missing oil leaking onto jack housing |